- RS Stock No.:
- 905-5535
- Mfr. Part No.:
- DT800000
- Brand:
- Red Lion
- RS Stock No.:
- 905-5535
- Mfr. Part No.:
- DT800000
- Brand:
- Red Lion
Technical data sheets
Legislation and Compliance
- COO (Country of Origin):
- US
Product Details
Red Lion Tachometer Counter
The Red Lion DT8 series 5-digit LCD electronic counter is a panel mount device. It has a supply voltage rating ranging between 9VDC and 28VDC. This is a DITAK-8 adjustable time base tachometer. This counter cannot reset manually with a maximum count frequency of 10kHz. The meter has been specifically designed for harsh industrial environments.
Features and Benefits
Meter accuracy is ±0.01%
Screw clamp type connection
Adjustable time base ranges between 4 millisecond and 63 second
Internal lithium battery provides over 5 years of continuous operation
Accepts magnetic or logic type signal inputs
Screw clamp type connection
Adjustable time base ranges between 4 millisecond and 63 second
Internal lithium battery provides over 5 years of continuous operation
Accepts magnetic or logic type signal inputs
Applications
Control and monitoring systems
Manufacturing assembly lines
Manufacturing assembly lines
Certifications
CE certified
EN 61010-1
IEC1010-1
IEC529
IP65 rated(Face Only)
Type 4X (Face Only)
UL50 listed
EN 61010-1
IEC1010-1
IEC529
IP65 rated(Face Only)
Type 4X (Face Only)
UL50 listed
Specifications
Attribute | Value |
---|---|
Supply Voltage | 9 → 28 V dc |
Display Type | LCD |
Input Type | Logic, Voltage |
Connection Type | Screw Clamp Terminal |
Reset Method | No Reset |
Number of Digits | 5 |
Mounting Type | Panel Mount |
Output / Interface | Voltage |
Digit Height | 15.2 mm |
Backlighting | Yes |
Maximum Count Frequency | 10Hz |
Cutout Size | 68 x 33 mm |
Function | Rate Meter |
Cutout Height | 33mm |
Series | DT8 |
Cutout Width | 68mm |
Depth | 35.1mm |
Meter Type | Electronic |
Minimum Operating Temperature | 0°C |
Approvals | CE, EN 61010-1, IEC 1010-1, IEC 529, IP65 (Face Only), Type 4X (Face Only), UL50 |
Maximum Operating Temperature | +60°C |
Meter Accuracy | ±0.01% |