A signal conditioner is a device that converts one type of electronic signal into another type of signal. Its primary use is to convert a signal that may be difficult to read by conventional instrumentation into a more easily read format. How it works Signal conditioning can perform a wide range of processes required to make sensor output suitable for processing include amplification, filtering, converting, range matching, isolation. The input from a sensor is connected to the signal conditioner, which is then able to convert the specific input type into a signal that produces the necessary output type for the instrumentation used. Types of Signal Conditioning • DIN Rail Mount - a DIN Rail mount signal conditioner mounts on a DIN Rail bracket and are very popular in industrial applications since they provide a rugged mounting format. • Backplane Mount Conditioners - The backplane style provides the advantage of all output signals being accessible through a single common connector. Backplane signal conditioners are often used with data acquisition systems. • Digital Sensor Signal Conditioners - The output of a digital signal conditioner is converted to a digital format such as RS232, RS485 or Ethernet. Digital signals provide a high degree of immunity from electrical noise, and can also support extended transmission distances.

...
Read more Read less

Filters

Viewing 61 - 80 of 532 products
Results per page
Description Price Input Type Output Type Signal Conditioner Type Input Range Output Range Supply Voltage Mounting Type Sensor Compatibility Minimum Operating Temperature Maximum Operating Temperature Hazardous Area Certification Interface Module Type Number of Channels
RS Stock No. 489-2904
Mfr. Part No.2864150
$456.41
Each
units
- Current, Voltage Isolation 0 → 10 V, 0 → 20 mA, 0 → 5 V, 1 → 5 V, 2 → 10 V, 4 → 20 mA 0 → 10 V, 0 → 20 mA, 0 → 5 V, 1 → 5 V, 2 → 10 V, 4 → 20 mA 24 V dc DIN Rail Potentiometer -20°C +65°C ATEX - - -
RS Stock No. 902-8066
Mfr. Part No.1066490000
BrandWeidmuller
$143.01
Each
units
- - - - - 42 V DIN Rail - -40°C +70°C IECEx - - -
RS Stock No. 849-6345
Mfr. Part No.2902055
$445.13
Each
units
Temperature Current, Voltage Temperature to Current, Temperature to Voltage -250 → +2500 °C 0 → 12.3 V, 0 → 24.6 mA 9.6 → 30 V dc DIN Rail Thermocouple -40°C +70°C - - - -
RS Stock No. 470-5850
Mfr. Part No.2864464
$394.66
Each
units
Current Relay Isolation 0 → 16 A - 20 → 30 V dc DIN Rail - -20°C +65°C - - - -
RS Stock No. 902-8060
Mfr. Part No.1065020000
BrandWeidmuller
$139.23
Each
units
- - - - - 35 V DIN Rail - -40°C +70°C IECEx - - -
RS Stock No. 902-8000
Mfr. Part No.8965360000
BrandWeidmuller
$267.31
Each
units
NAMUR Sensor NPN NAMUR Sensor to NPN 8 V dc <2.5 V dc 19.2 → 31.2 V DIN Rail NAMUR Sensor -20°C +60°C IECEx USB Cable Signal Isolating Converter 1
RS Stock No. 418-4966
Mfr. Part No.3RS1705-1FW00
BrandSiemens
$700.04
Each
units
Analogue Analogue Analogue to Analogue 0 → 10 V, 0 → 20 mA 0 → 10 V, 0 → 20 mA 24 → 240 V ac/dc DIN Rail - -25°C +60°C - - - -
RS Stock No. 902-8063
Mfr. Part No.1063930000
BrandWeidmuller
$103.02
Each
units
- - - - - 42 V DIN Rail - -40°C +70°C IECEx - - -
RS Stock No. 321-6646
Mfr. Part No.2814511
$730.65
Each
units
- Voltage - 4 → 20 mA 0 → 10 V 20 → 30 V dc DIN Rail - -25°C +60°C - - - -
RS Stock No. 902-8026
Mfr. Part No.8965430000
BrandWeidmuller
$405.66
Each
units
Analogue Analogue Analogue to Analogue 4 → 20 mA 4 → 20 mA 19.2 → 31.2 V DIN Rail HART Signal Protocol -20°C +60°C IECEx USB Cable Signal Isolating Converter 1
RS Stock No. 489-2847
Mfr. Part No.2864419
$335.81
Each
units
Current Analogue Isolation 0 → 20 mA 0 → 20 mA 18 V DIN Rail Potentiometer -20°C +65°C - - - -
RS Stock No. 902-8082
Mfr. Part No.8953670000
BrandWeidmuller
$144.30
Each
units
- - - - - 26 V DIN Rail PT100 -40°C +70°C IECEx - - -
RS Stock No. 796-7076
Mfr. Part No.3103
$264.96
Each
units
Analogue Current Analogue to Current 0 → 20.5 mA 0 → 20.5 mA 16.8 → 31.2 V dc DIN Rail - -25°C +70°C ATEX - - -
RS Stock No. 736-4752
Mfr. Part No.SG45-115-00000-000
BrandP.M.A
$693.69
Each
units
Digital Analogue Digital to Analogue 5 V 0 → 10 V, 0 → 20 mA, 14 bit 18 → 30 V ac, 18 → 31 V dc DIN Rail Load Cell, Melt Pressure Sensor, Strain Gauges -20°C +60°C - - - -
RS Stock No. 785-7783
Mfr. Part No.2902851
$339.81
Each
units
Temperature Current, Voltage Temperature to Current, Temperature to Voltage -250 → +2500 °C 0 → 10 V, 0 → 20 mA, 0 → 5 V, 1 → 5 V, 10 → 0 V, 20 → 0 mA, 20 → 4 mA, 4 → 20 mA 9.6 → 30 V dc DIN Rail Thermocouple -20°C +65°C - - - -
RS Stock No. 796-6887
Mfr. Part No.4114
$374.89
Each
units
Analogue Current Analogue to Current 0 → 12 V dc, 0 → 20 mA, 4 → 20 mA, 10 MΩ, 20 Ω 0 → 10 V dc, 0 → 20 mA 19.2 → 300 V dc, 21.6 → 253 V ac DIN Rail Linear Resistance, Potentiometer, RTD, Thermocouple -20°C +60°C - - - 1
RS Stock No. 796-6881
Mfr. Part No.5116A
$864.64
Each
units
Analogue Current Analogue to Current 0 → 100 mA, 0 → 250 V dc, 10 MΩ, 10 Ω 0 → 20 mA 19.2 → 300 V dc, 21.6 → 253 V ac DIN Rail Linear Resistance, Potentiometer, RTD, Thermocouple -20°C +60°C - - - -
RS Stock No. 796-6913
Mfr. Part No.4131
$350.39
Each
units
Analogue Relay Analogue → Relay 0 → 12 V dc, 0 → 20 mA 2 A, 250 V 19.2 → 300 V dc, 21.6 → 253 V ac DIN Rail RTD, Thermocouple -20°C +60°C - - - -
RS Stock No. 324-0661
Mfr. Part No.PXT-10.024/RS
$308.72
Each
units
Temperature Analogue Temperature to Analogue -50 → 300 °C 0 → 10 V dc, 0 → 20 mA 24 V ac DIN Rail RTD -20°C +55°C - - - -
RS Stock No. 460-409
Mfr. Part No.1SNA684252R0200
BrandABB
$897.25
Each
units
RS232 Ethernet RS232 to Ethernet - - 10 → 24 V ac, 10 → 30 V dc Snap-On - 0°C +60°C - - - -
Related Products
The MTL5500 series is the latest generation of ...
Description:
The MTL5500 series is the latest generation of MTL isolators. Incorporating advanced circuit design and innovative isolating transformer construction. The compact 16mm wide design reduces weight and gives a high packing density and reduction in power consumption. They build on ...
Symmetric DIN rail mounting units with finger protected ...
Description:
Symmetric DIN rail mounting units with finger protected terminals designed for use in process control and instrumentation applications. Single or dual level trip amplifiers from a single Input.Each trip can be arranged so that the alarm condition can be above ...
RS Pro isolating signal converters for converting a ...
Description:
RS Pro isolating signal converters for converting a range of process signals into standard active and passive transmission current or voltage signals. AC supply voltage. Fully isolated – Input/Supply/Output. Signals conditioned before being fed through opto-isolating circuit. Red LED power ...
CC-E measuring converter without auxiliary power for sinusoidal ...
Description:
CC-E measuring converter without auxiliary power for sinusoidal currents (0-1 A, 0-5 A). Measuring range selection by front-face sliding switch4-20 mA output current in proportion to input current. No additional power supply required.