Sifam Tinsley DC Analogue Voltmeter, 75mV, 27 (Dia.) mm, ±1.5 % Accuracy

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): GB
Product Details

Presentor Range DC Meters

Electrical connections via 6mm tag terminals
Accuracy classes BS89; IEC51 and EN60051
Operating temperature range –25 to +55°C
Front mounting panel cut-out 27mm diameter in maximum panel thickness of 4mm
Rear mounting panel cut-outs (with bezel) in a maximum panel thickness of 6mm
Fixing stud sizes: M2 x 10.0mm (for 43.9 x37.9mm), M2.5 x 10.0mm (for other sizes)

//media.rs-online.com/t_line/L196827-02.gif
//media.rs-online.com/t_line/LF196827-99.gif
//media.rs-online.com/t_line/LI196827-01.gif

Standards

BS89, IEC51, EN60051

Moving Coil DC Meters

Specifications
Attribute Value
Current Type DC
Cutout Size 27 (Dia.) mm
Cutout Height 59mm
Cutout Width 76mm
Maximum Displayed Value 75mV
Meter Accuracy ±1.5 %
Depth 30.5mm
Minimum Temperature -25°C
Maximum Temperature +55°C
Meter Type Moving Coil
21 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 93.38
(exc. GST)
$ 107.39
(inc. GST)
units
Per unit
1 - 4
$93.38
5 - 9
$91.04
10 +
$88.65
Related Products
Polarised moving-iron meters with robust movements for use ...
Description:
Polarised moving-iron meters with robust movements for use on dc and rectified ac only. Accuracy ±8% for battery charger applications. Operating temperature range –20 to +40°CSnap-in panel fixing. Connections 25mm, 1//4 inch spade terminals, push-on or soldered’U’ bolt fixing.
Performance based on BS6840:Part 17:1991 & IEC 268-17:1990, ...
Description:
Performance based on BS6840:Part 17:1991 & IEC 268-17:1990, which cover dynamic characteristics, frequency response, harmonic distortion, input impedance and temperature range. Calibrated for use with a 3.6kΩ resistor 4VU above the scale marking so that reference deflection (0VU) is produced ...
DQB permanent-magnet moving-coil instruments measure direct currents. If ...
Description:
DQB permanent-magnet moving-coil instruments measure direct currents. If a meter rectifier is used, the average value of a rectified alternating current can also be determined. Measurement accuracy: Class 1.5 (= max. error 1.5% of final value)Front: 96 x 96 mm. ...
These Sigma Series of DE moving coil panel ...
Description: