Fluke 772 Clamp Meter, 100mA dc

  • RS Stock No. 669-3490
  • Mfr. Part No. Fluke 772
  • Manufacturer Fluke
Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): CN
Product Details

772 & 773 Milliamp Process Clamp Meters

Need more hours in your day? Save time by not breaking the loop on 4-20 mA signal measurements with the Fluke 771 Process Clamp Meter.

Are you spending time:

•Taking mA measurements by removing a wire and breaking the loop •Calling the control room to isolate a loop
•Testing analog input/output on a console
•Troubleshooting devices with mA inputs and outputs
•Repairing intermittent or erratic 4-20 mA loops
•Going back to the shop to get extra tools

If you need more time in your busy day take a good look at the Fluke 772 and 773 mA Clamp Meters. Designed to save you time, and money, by eliminating time wasting activities. Now you can troubleshoot and repair 4-20 mA loops without breaking the loop or bringing down the system.

Here are some specific ways the Fluke 772 and 773 clamp meters will help you:

Measure mA signals for PLC and control system analog I/O without breaking the loop
•Measures low level dc current
•Correlate process indication with real physical value

Measure output signals from transmitters without breaking the loop
•Maintain and troubleshoot process and automation equipment without breaking the loop
•No disruption to the process

Detachable clamp with extension cable
•Measurements in tight locations
•Enables measurements in difficult situations

Measurement Spotlight
•Illuminates hard to see wires in dark enclosures
•Measurement process is easier and quicker

Measure up to 99.9 mA range non-contact
•Wide range of measurements
•Measures 10 to 50 mA signals in older control systems

Automatic power off
•After 15 minutes and 2 minute automatic off for backlight and spotlight
•Saves battery life

Want simultaneous mA source/measure? Consider the Fluke 773 Milliamp Clamp Meter.

Features and Benefits

•Best in class 0.2% accuracy
•0.01 mA resolution and sensitivity
•Measure 4 to 20 mA signals without “breaking the loop”
•Measure mA signals for PLC and control system analog I/O
•Dual backlit display with both mA measurement and percent of 4 to 20 mA span
•Measurement Spotlight illuminates hard to see wires in dark enclosures
•Detachable clamp with extension cable for measurements in tight locations
•Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
•Automatically change the 4 to 20 mA output for remote testing
•Power saving features, auto-off, backlight timeout extend battery life
•Hold function captures and displays changing measurements
•Measure 4 to 20 mA signals with in-circuit measurement
•Simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters
•Source 4 to 20 mA signals for testing control system I/O or I/Ps
•mA output linear ramp or 25% step output
•Automatically change the 4 to 20 mA output for remote testing

Fluke 772 additional features:

Source 4 to 20 mA signals for testing control system I/O or I/Ps Simulate 4 to 20 mA signals for testing control system I/O
Measure 4 to 20 mA signals with in-circuit measurement
Simultaneously measure mA in-circuit with 24 V loop power for powering and testing transmitters
Source mA output signals in a linear ramp or 25 % step output for remote testing
Power saving features, auto-off, backlight timeout extend battery life

Fluke 773 additional features:

DC voltage measurement to verify 24 V power supplies or voltage I/O signals
Source dc voltage to test input devices that accept a 1 to 5 volt or 0 to 10 volt signal
Scaled mA output corresponds to the 4 to 20 mA signal measured by the mA clamp enables a logging DMM or other device to record the 4 to 20 mA signal without breaking the loop mA in/out: simultaneously measure the mA signal with the clamp and source a mA signal
Voltage output linear ramp or 25 % step output
Automatically change the voltage output for remote testing

Note

For details of the 771 process clamp meter see stock no. 287-642

Supplied with

4 AA alkaline batteries, test lead set with integral prods and 2 crocodile clips; test leads with integral grabber clips; soft carry case & instructions

Specifications
Attribute Value
Absolute Maximum AC Current Measurement -, - A ac
Absolute Maximum DC Current Measurement 99.9mA dc
Model Number 772
DC Current Measurement Resolution 10uA
Best DC Current Accuracy ±1% + 5 Digits
Clamp Meter Type Milliamp Process Clamp
Weight 420g
Height 41mm
Functions Measured AC Current
Maximum Operating Temperature +50°C
Jaw Capacity Busbars 4.5mm
Minimum Operating Temperature -10°C
Battery Life 20 h
Maximum Conductor Size 4.5mm
Dimensions 248 x 76 x 41mm
Length 248mm
Battery Type AA
Width 76mm
Power Source Battery
Display Type LCD
3 In stock for delivery within 1 working day(s)
Price (ex. GST) Each
$ 1,580.70
(exc. GST)
$ 1,817.80
(inc. GST)
units
Per unit
1 +
$1,580.70
Related Products
CAT.IV Clamp Meters can measure voltages and currents ...
Description:
CAT.IV Clamp Meters can measure voltages and currents in both very low and high power circuits6039 counts with Bar Graph displayRed LED, as "Non Contact Voltage" function, gives warning to the user of the presence of AC VoltagesMIN/MAX measurement functionDouble-moulded ...
Designed to verify the presence of load current, ...
Description:
Designed to verify the presence of load current, voltage and resistence, etc.The small bodies and jaws fit perfectly in your hand and a large backlit display is easy to read.Test lead mA range with high 1 mA resolution for HVAC ...
Standard: IEC 1010-1, 600 V Cat. III, deg. ...
Description:
Standard: IEC 1010-1, 600 V Cat. III, deg. 2 if used with a multimeter of the same category. Current probes to measure low DC and AC currents.Easily adapted to all 19 mm standard spacing multimeters.Zero reset using a thumb wheel ...
4000 count LCD displayAC & DC Current MeasurementTrue ...
Description:
4000 count LCD displayAC & DC Current MeasurementTrue RMS measurements with auto rangeHigh noise rejection ideal for testing AC power distribution control gear and AC/DC inverter drive systemsHigh external field rejectionHigh accuracy over full rangeSimple push button for data hold ...