- RS Stock No.:
- 766-0624
- Mfr. Part No.:
- P01120966
- Brand:
- Chauvin Arnoux
- RS Stock No.:
- 766-0624
- Mfr. Part No.:
- P01120966
- Brand:
- Chauvin Arnoux
Technical data sheets
Legislation and Compliance
- COO (Country of Origin):
- CN
Product Details
Clamp multimeter F606
2,000 A TRMS AC+DC multimeter clamp
With protection against electric shocks up to 12 kV, the F600 Series fulfils the most demanding safety criteria (CAT IV 1,000 V) and offers a high protection rating allowing users to work in total safety on all LV installations.
The F600 Series is ideal for high-power applications such as electrical power distribution, chemical and petrochemical industries, metallurgy, rail transport, etc.
Equipped with a fast 12-bit TRMS digital acquisition system, F606 clamps offer particularly accurate measurements whatever the signal's waveform.
With protection against electric shocks up to 12 kV, the F600 Series fulfils the most demanding safety criteria (CAT IV 1,000 V) and offers a high protection rating allowing users to work in total safety on all LV installations.
The F600 Series is ideal for high-power applications such as electrical power distribution, chemical and petrochemical industries, metallurgy, rail transport, etc.
Equipped with a fast 12-bit TRMS digital acquisition system, F606 clamps offer particularly accurate measurements whatever the signal's waveform.
Specifications:
• Clamping diameter: 60 mm
• Current: 2,000 A AC / 3,000 A DC
• Voltage up to 1,200 VAC / 1,700 VDC
• Resistance and audible continuity
• Power values (W, var, VA, PF) and harmonics (THDf, THDr)
• "2-wire method" phase rotation
• Automatic AC/DC detection
• TrueInrush current measurement
• Min, MAX, Peak+, Peak-
• RELative (ΔX) and differential (ΔX/X) measurements
• CAT IV 1,000 V / CAT III 1,500 V
• IP54 protection rating
• Current: 2,000 A AC / 3,000 A DC
• Voltage up to 1,200 VAC / 1,700 VDC
• Resistance and audible continuity
• Power values (W, var, VA, PF) and harmonics (THDf, THDr)
• "2-wire method" phase rotation
• Automatic AC/DC detection
• TrueInrush current measurement
• Min, MAX, Peak+, Peak-
• RELative (ΔX) and differential (ΔX/X) measurements
• CAT IV 1,000 V / CAT III 1,500 V
• IP54 protection rating
Specifications
Attribute | Value |
---|---|
Absolute Maximum AC Current Measurement | 2000A ac |
Absolute Maximum DC Current Measurement | 3000A dc |
Absolute Maximum AC Voltage Measurement | 1200V ac |
Absolute Maximum DC Voltage Measurement | 1700V dc |
Absolute Maximum Resistance Measurement | 99.99kΩ |
Model Number | F606 |
AC Current Measurement Resolution | 10mA |
DC Current Measurement Resolution | 10mA |
Best DC Current Accuracy | ±(1% rdg + 3dgts) |
Clamp Meter Type | AC/DC Clamp Meter |
Best AC Current Accuracy | ±(1% rdg + 3dgts) |
Best AC Voltage Accuracy | ±(1% rdg + 3dgts) |
Functions Measured | AC Current, AC Voltage, Continuity, DC Current, DC Voltage, Diode, Frequency, Harmonics, In-Rush Current, Phase rotation, Power, Power Factor, Resistance |
True RMS | Yes |
Best DC Voltage Accuracy | ±(1% rdg + 3dgts) |
Jaw Capacity Busbars | 60mm |
Display Type | Backlit LCD |
Battery Life | 350 h |
Best Resistance Measurement Accuracy | ±1 % + 5 digits |
Maximum Conductor Size | 60mm |
Maximum Operating Temperature | +55°C |
Safety Category Voltage | CAT III 1500 V, CAT IV 1000V |
Safety Category Level | CAT III, CAT IV |
Safety Category | CAT III 1500 V, CAT IV 1000V |
AC Current Measurement Range | 0.25 to 2000 A AC |
Battery Type | AA |
Weight | 640g |
AC Voltage Measurement Range | 0.15 to 1200 V AC |
AC Voltage Measurement Resolution | 10mV |
Height | 41mm |
Length | 296mm |
Width | 111mm |
Non-Contact Voltage Detector | No |
Power Source | Battery |
Minimum Operating Temperature | -20°C |
DC Voltage Measurement Resolution | 10mV |
Dimensions | 111 x 41 x 296mm |
DC Current Measurement Range | 0.25 to 3000 A DC |
Resistance Measurement Resolution | 100mΩ |