LEM HXS Series Open Loop Current Sensor, ±60A

  • RS Stock No. 532-9081
  • Mfr. Part No. HXS 10-NP/SP3
  • Manufacturer LEM
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): BG
Product Details

HXS Series

PCB mounting Hall Effect current transducers designed around a proprietary ASIC.

AC,DC, and mixed current measurement
Unipolar 5V supply
Low power consumption
Extremely low profile
Reference in/out
Integral Primary
Operating Temperature Range -40 to +85°C except for NP/SP2 units at -40 to 105°C

Specifications
Attribute Value
Sensor Technology Open Loop
Nominal Current ±60A
Supply Voltage 5 V
Sensor Type Hall Effect
Mounting Type PCB Mount
Frequency Bandwidth DC to 50 kHz
Accuracy ±1 %
Series HXS
Minimum Operating Temperature -40°C
Maximum Operating Temperature +85°C
Depth 18.7mm
Height 10.7mm
Width 16.7mm
689 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 20.89
(exc. GST)
$ 24.02
(inc. GST)
units
Per unit
1 - 5
$20.89
6 - 11
$20.23
12 +
$20.05
Related Products
The CMS2000 current sensor family from Sensitec are ...
Description:
The CMS2000 current sensor family from Sensitec are compact devices offering accurate current measurement. They are able to provide measurement for AC, DC and mixed currents featuring integrated galvanic isolation.Designed for industrial applications, the CMS2000 current sensors are based on ...
Single-pole Hall effect current transducers. Measurement of inserted ...
Description:
Single-pole Hall effect current transducers. Measurement of inserted conductor. Voltage output, Vout = ±4VCapable of measuring complex signals. Excellent precision and good linearity. Low temperature drift. Body material Plastic; Polycarbonate PBTOperating Temperature Range -10 to +80°CSecondary connector: stock ...
Passive current transformers without auxiliary power. Convert ac ...
Description:
Passive current transformers without auxiliary power. Convert ac into analogue signals 1 to 20mA or 0 to 10VLimit monitor. Limit value and alarm suppression time set by two potentiometers1 NO, 1NC relay contact.
Open Loop Hall Effect current transducers with integral ...
Description:
Open Loop Hall Effect current transducers with integral primary connections for the accurate measurement of current. Open Loop (low power consumption)AC,DC, and mixed signal measurement. Extended measuring range (3xlpn)Small sizeHX 03-20 (23.5x15.8x19mm)HX 25-50 (20x19x15.4mm)Multi turn Primary. Unipolar power ...