Phoenix Contact PACT RCP, DIN Rail Mounted Circuit Transformer,

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

Set consisting of a 4-way signal conditioner with screw connection technology and a Rogowski coil 450 mm in length/140 mm in diameter for AC current measurement on busbars and power lines. The signal conditioner outputs 8 different standard signals on the output side and has one switching output.

Specifications
Attribute Value
Transformer Type DIN Rail Mounted
Overall Height 120.5mm
Overall Width 6.2mm
Overall Depth 110.5mm
Input Current 1 kA, 1.5 kA, 2 kA, 4 kA, 100 A, 250 A, 400 A, 630 A
Output Current 0 → 21 mA
Minimum Temperature -40 °C, -30 °C
Maximum Temperature +70 °C, +80 °C
Dimensions 6.2 x 110.5 x 120.5 mm
Mounting Type DIN Rail
Series PACT RCP
For Use With Retrofitting
On back order for despatch 20/01/2020, delivery within 5 working days from despatch date.
Price (ex. GST) Each
$ 668.02
(exc. GST)
$ 768.22
(inc. GST)
units
Per unit
1 +
$668.02
Related Products
Power consumption 2.5VA, 50/60Hz. Accuracy class120, 30 or ...
Description:
Power consumption 2.5VA, 50/60Hz. Accuracy class120, 30 or 40mm busbar mounting. Suitable for circular conductors 35mm aperture. Maximum aperture for bar conductors 40x10mm (type 7)Operating temperature range –30 to +85°CSecondary terminals M5 studs with lock washers, nuts and terminal cover. ...
A range of compact moulded case current transformers ...
Description:
A range of compact moulded case current transformers suitable for primary currents from 40A to 300A with built in sealable terminal covers. For transforming various primary currents into 5A standard secondary using up to 20mm diameter cables. DIN rail mounting ...
Moulded case with sliding sealable terminal covers. Operating ...
Description:
Moulded case with sliding sealable terminal covers. Operating temperature range –30 to +85°CScrew or push on terminal connectors. Secondary terminals M5 studs with washers, lock washers and nuts. Narrow width allows close mounting between busbars. Insulation voltage 0.72/3kV125 x 66 ...
Core Balanced Current Transformers suitable for the GIC ...
Description:
Core Balanced Current Transformers suitable for the GIC Earth Leakage Relays.When an earth leakage occurs the resulting imbalance generates a proportional current in the Core Balanced Current Tranformers.The output of Core Balanced Current Tranformers is connected to the GIC Earth ...