Sick Vertical Mounting Level Radar 0-10 V, 4-20 mA Output IO-Link

  • RS Stock No. 794-3383
  • Mfr. Part No. LFP1000-A4NMB
  • Manufacturer Sick
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

SICK Guided Radar Level Detection

A range of guided radar level detection units from SICK. Using TDR (time domain reflectrometry), time of flight technology these level sensors use contact type level measurement to detect and monitor levels in both water and oil based fluids. Offering accurate and reliable measurement that is unaffected by environmental and physical conditions such as temperature, pressure, agitated surfaces, viscosity or acidity. SICK’s range of guided radar level sensors can be mounted close to each other without crosstalk and accuracy is unaffected by deposit build-up on the probe.
LFP Inox models have been specifically designed for hygienic applications and are CIP and SIP resistant
(see stock numbers 794-3395, 794-3399, 794-3709)

Four button set-up
No requirement for calibration or re-calibration
3 in 1 Combination, Display, analog and binary outputs
Simultaneous level detection and continuous monitoring output capability
High Accuracy measurement in difficult conditions
Compact design
Rotatable housing
IP67 Rated enclosure
Probe length can be easily modified to suit application.
No moving parts

Specifications
Attribute Value
Device Type Guided Radar
Mounting Type Vertical
Switch Output 0-10 V, 4-20 mA
Body Material PBT
Minimum Operating Temperature -20°C
Maximum Operating Temperature +100°C
Maximum Current 100 mA
Maximum Pressure 10bar
Gasket Material PTFE
Interface IO-Link
6 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 549.78
(exc. GST)
$ 632.25
(inc. GST)
units
Per unit
1 +
$549.78
Related Products
Radar transducer for fill level and volume measurement ...
Description:
Radar transducer for fill level and volume measurement of liquids and slurries in storage and process vessels. One-piece polypropylene rod antenna. Simple installation and commissioning. Programming with intrinsically safe infra-red hand programming device.
Flowline Echo. Pro LR16 intrinsically safe 26 GHz ...
Description:
Flowline Echo. Pro LR16 intrinsically safe 26 GHz pulse radar transmitter provides continuous level measurement up to 30 m with a 4 to 20 mA analogue and HART digital signal output. Configurable via an integral push button display module or ...
Flowline Echo. Pro LR31 intrinsically safe 26 GHz ...
Description:
Flowline Echo. Pro LR31 intrinsically safe 26 GHz pulse radar transmitter provides continuous level measurement up to 20 m with a 4 mA to 20 mA analogue and HART digital signal output. Configurable via a remote push button display module ...
CE marked in compliance with relevant European Directives. ...
Description:
CE marked in compliance with relevant European Directives. Sensing range 2 to 10mm adjustable via a single turn potentiometerLED indication when activated. Output: DC 100mA transistor. Power ON delay; Max 40ms (No delay version), Max 5s (ON/OFF delay versions)Supply voltage; ...