Schneider Electric Acti 9 iC60H MCB Mini Circuit Breaker 1P, 4 A, 10 KA, Curve B

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): BG
Product Details

Schneider Electric Acti9 iC60H MCBs 1 Pole

C60H series multi-standard circuit breakers combine circuit protection against short circuit currents and circuit protection against overload currents it also protects people against indirect contact with TN and IT neutral systems. Fully compliant with standards IEC/EN 60898 and IEC/EN 60947-2. ACTi 9 is fully tested, approved and certified by national and international third parties. It guarantees that your installation is safe and compliant with all relevant safety standards which demonstrates to your customers that you use industry-approved materials and best practices. These MCBs are normally used for high inductive loads where switching surges are high. Providing essential protection in industrial and commercial buildings, these miniature circuit breakers work especially well in polluted environments and networks.

Features and benefits:

VisiSafe guarantees the downstream circuit is always safe regardless of overvoltage conditions, even in the most demanding environments; the green strip indicates the safe position of contacts.
VisiTrip red window on the front face indicates fault tripping allowing fast diagnosis, resolution, and reclosing loads for easier building management and reduced downtime

Benefits and Features

• Downstream circuit is always safe
• Class-2 insulation: ensures continuous protection for both operators and unqualified persons
• Insulated terminals (IP20)
• Highly durable with robust connections that provide twice the standard tightening torque
• Provide greater continuity of service thanks to VisiTrip
• Double clip for dismounting with comb busbar in place

Applications -

Standards

IEC 60898 - Relates to Low Voltage Circuit Breakers for use in household and similar
Installations. In the UK traditionally known as miniature circuit breakers
(MCB’s).
IEC 60947-2 Relates to Low Voltage Circuit Breakers for use in industrial and similar
Installations. In the UK traditionally known as moulded case circuit breakers
(MCCB’s) and also air circuit breakers (ACB’s).

Q: What is the differences in the Tripping Curves B, C, and D?

A: Curve B: Tripping: 3 to 5 times the rated current.
Applications: protection of generators, persons, very long cables
Curve C: Tripping: 5 to 10 times the rated current
Applications: protection of circuits and general applications
Curve D: Tripping: 10 to 14 times the rated current
Applications: protection of high surge circuits, welders, transformers and motors

Note

The Acti9 come in either Curve B , C or D. Please refer to specifications for specific type.

A9F53104 Schneider Electric MCB

This model has tripping curve type B that trips instantly at a rate of 3 to 5 times the rated current 1 pole breaker and a breaking capacity of 10 kA.

Merlin Gerin – MCBs

Miniature Circuit Breakers; Contact Position indicated by switch levers

Specifications
Attribute Value
Range Acti 9
Series iC60H
Number of Poles 1
Current Rating 4 A
Tripping Characteristics Type B
Rated AC Voltage 12 → 60 V, 100 → 133 V, 220 → 240 V
Mounting Style DIN Rail
Rated DC Voltage 12 → 48 V, 72 V
Breaking Capacity 10 kA
Length 85mm
Width 18mm
Depth 78.5mm
Terminal Contact Type Screw
Reset Actuator Type Rocker
Circuit Breaker Type MCB
Tripping Mechanism Thermal-Magnetic
3 : Next working day
65 Within 5 working day(s) (Global stock)
Price (ex. GST) Each
$ 50.02
(exc. GST)
$ 57.52
(inc. GST)
units
Per unit
1 +
$50.02
Related Products
Acti 9 DCP H Vigi - RCBO - ...
Description:
Acti 9 DCP H Vigi - RCBO - 2P - 20A - C Curve - 10000A/10kA - 30mA - type A.
Miniature Circuit Breakers; Contact Position indicated by switch ...
Description:
Miniature Circuit Breakers; Contact Position indicated by switch levers. B, C and D curve. Visisafe green strip indicates and guarantees the safe position of contacts. VisiTrip red window on the front face indicates fault tripping allowing fast diagnosis, resolution, and ...
This range of supplementary protectors are used in ...
Description:
This range of supplementary protectors are used in direct current circuits (Industrial control and automations, transport, renewable energy).They combine the following functions of circuit protection against short-circuit and overload currents, control and isolation. Tripping curves: C curve - Overcurrent ...
Acti 9 Schneider iC60N series multi-standard circuit breakers ...
Description:
Acti 9 Schneider iC60N series multi-standard circuit breakers combine circuit protection against short circuit currents and circuit protection against overload currents it also protects people against indirect contact with TN and IT neutral systems. Fully compliant with standards IEC/EN 60898 ...