Schneider Electric Acti 9 iC60H MCB Mini Circuit Breaker 1P, 20 A, 10 KA, Curve D

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): BG
Product Details

Schneider Electric Acti9 iC60H MCBs 1 Pole

C60H series multi-standard circuit breakers combine circuit protection against short circuit currents and circuit protection against overload currents it also protects people against indirect contact with TN and IT neutral systems. Fully compliant with standards IEC/EN 60898 and IEC/EN 60947-2. ACTi 9 is fully tested, approved and certified by national and international third parties. It guarantees that your installation is safe and compliant with all relevant safety standards which demonstrates to your customers that you use industry-approved materials and best practices. These MCBs are normally used for high inductive loads where switching surges are high. Providing essential protection in industrial and commercial buildings, these miniature circuit breakers work especially well in polluted environments and networks.

Features and benefits:

VisiSafe guarantees the downstream circuit is always safe regardless of overvoltage conditions, even in the most demanding environments; the green strip indicates the safe position of contacts.
VisiTrip red window on the front face indicates fault tripping allowing fast diagnosis, resolution, and reclosing loads for easier building management and reduced downtime

Benefits and Features

• Downstream circuit is always safe
• Class-2 insulation: ensures continuous protection for both operators and unqualified persons
• Insulated terminals (IP20)
• Highly durable with robust connections that provide twice the standard tightening torque
• Provide greater continuity of service thanks to VisiTrip
• Double clip for dismounting with comb busbar in place

Applications -

Standards

IEC 60898 - Relates to Low Voltage Circuit Breakers for use in household and similar
Installations. In the UK traditionally known as miniature circuit breakers
(MCB’s).
IEC 60947-2 Relates to Low Voltage Circuit Breakers for use in industrial and similar
Installations. In the UK traditionally known as moulded case circuit breakers
(MCCB’s) and also air circuit breakers (ACB’s).

Q: What is the differences in the Tripping Curves B, C, and D?

A: Curve B: Tripping: 3 to 5 times the rated current.
Applications: protection of generators, persons, very long cables
Curve C: Tripping: 5 to 10 times the rated current
Applications: protection of circuits and general applications
Curve D: Tripping: 10 to 14 times the rated current
Applications: protection of high surge circuits, welders, transformers and motors

Note

The Acti9 come in either Curve B , C or D. Please refer to specifications for specific type.

Merlin Gerin – MCBs

Miniature Circuit Breakers; Contact Position indicated by switch levers

Specifications
Attribute Value
Range Acti 9
Series iC60H
Number of Poles 1
Current Rating 20 A
Tripping Characteristics Type D
Rated AC Voltage 12 → 60 V, 100 → 133 V, 220 → 240 V
Rated DC Voltage 12 → 48 V, 72 V
Mounting Style DIN Rail
Breaking Capacity 10 kA
Length 85mm
Width 18mm
Depth 78.5mm
Terminal Contact Type Screw
Circuit Breaker Type MCB
Reset Actuator Type Rocker
Tripping Mechanism Thermal-Magnetic
28 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 44.97
(exc. GST)
$ 51.72
(inc. GST)
units
Per unit
1 +
$44.97
Related Products
Acti 9 DCP H Vigi - RCBO - ...
Description:
Acti 9 DCP H Vigi - RCBO - 2P - 20A - C Curve - 10000A/10kA - 30mA - type A.
MEM 250V DIN rail mount RCD’s and MCB’s ...
Description:
MEM 250V DIN rail mount RCD’s and MCB’s etc, for use as spares and replacements in Memera consumer units. Complies with BS EN 60898Accept cable up to 25mm²Thermal/magnetic operation. Positive contact indication (red-on, green-off)1, 2 or 3 pole.
ABB System pro M compact S200M miniature circuit ...
Description:
ABB System pro M compact S200M miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electro mechanic tripping mechanism for short circuit protection. All MCBs of the ...
Automatic Cut-Out, 1-Pole and 3-PoleDIN rail assembly. For ...
Description:
Automatic Cut-Out, 1-Pole and 3-PoleDIN rail assembly. For use in industry and in the functional sector.