Schneider Electric Current Monitoring Relay With DPDT Contacts, 3 Phase, 323 → 456.5 V ac

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): ID
Product Details

RM35 JA Series Current Control Relay

Schneider Electric RM35 JA current control relay for controlling alternating and direct currents in the event of under or overcurrent. Automatic alternating or direct current recognition and a wide measurement range. Monitors heating and lighting circuits and motor and generator load status.

Checks its own power supply
Clear hinged front cover
LED display of output status
DIN Rail mounting

Standards

NF EN 60255-6 and IEC 60255-6

Approvals

UL, CSA, GL, C-Tick, GOST

Schneider Electric Voltage, Current, Phase & Motor Protection

Specifications
Attribute Value
Monitoring Application Current
Supply Voltage 323 → 456.5 V ac
Contact Configuration DPDT
Electrical Phase 3
Current Sensitivity Overcurrent, Undercurrent
Minimum Current Sensed 150mA
Maximum Current Sensed 15A
Time Delay 0.1 → 30 s
Current Range 150 mA → 15 A
Series RM35JA
Minimum Operating Temperature -20°C
Maximum Operating Temperature 60°C
Length 35.6mm
Width 72.05mm
Number of Poles 2
Dimensions 35.6 x 72.05 x 90 mm
Terminal Type Screw
Mounting Type DIN Rail
Height 90mm
Standards Met CCC, CE, CISPR 11, CISPR 22, CSA, EAC, EN/IEC 60255-1, EN/IEC 60715, GL, IEC 60068-2-27, IEC 60068-2-30, IEC 60068-2-6, IEC 60529, IEC 60664-1, IEC 60947-1, IEC 60947-4-1, IEC 60947-5-1, IEC 6100, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5
Operating Temperature Range -20 → +60 °C
2 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 249.43
(exc. GST)
$ 286.84
(inc. GST)
units
Per unit
1 +
$249.43
Related Products
TELE KAPPA series AC and DC voltage monitoring ...
Description:
TELE KAPPA series AC and DC voltage monitoring relay. Multifunction monitoring in a slim easy to use package. The KAPPA series have a self-extinguishing plastic body with an IP rating of IP40. DIN Rail mountLED indicator. Screw terminals2 change over ...
The DPD Series settings can easily be modified ...
Description:
The DPD Series settings can easily be modified through an Android App via a smartphone/tablet or via a USB NFC Reader/Writer connected to a computer. Under and over threshold settings can be set, as well as hysteresis and time delays. ...
Multi range. Adjustable hysteresis. Latching facility. Adjustable fault ...
Description:
Multi range. Adjustable hysteresis. Latching facility. Adjustable fault delay. Adjustable start -up delay. Switchable relay inversionLED indication. Write on ID tab. Dimensions: H78 x W45 x D99mm.
Detects Over frequencyOFR relay energises if frequency rises ...
Description:
Detects Over frequencyOFR relay energises if frequency rises above trip level – red LED off, contacts 11, 12 /21 & 22Adjustable trip level: 40 → 60Hz. Adjustable hysteresis. Monitors own supply1 x DPDT relay output: 8ALED indication for supply and ...