ABB Optocoupler, Max. Forward 115 V, Max. Input 4.2 mA, 75mm Length, DIN Rail Mounting Style

  • RS Stock No. 773-0115
  • Mfr. Part No. 1SNA645554R0100
  • Manufacturer ABB
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
Product Details

CC-E Series Temperature Converters

Analogue converters for Pt100 probes
Provides triple galvanic insulation between 2 (1.5 kV) input, output and supply signals
Connection using 2 or 3 wires, wide range of temperatures
Selection of input and output via switches
DIN rail mounted

ABB DIN Rail Signal Converters, Analogue

All units suitable for use within ambient temperature range from : -20 to +60°C. Module dimensions: H105 x W22.5 x D129.5mm

Specifications
Attribute Value
Maximum Forward Voltage 115 V
Maximum Input Current 4.2 mA
Isolation Voltage 2.5kVrms
Mounting Style DIN Rail
Minimum Operating Temperature -20°C
Maximum Operating Temperature +70°C
Length 75mm
Width 6mm
Depth 75mm
Dimensions 75 x 6 x 75 mm
Operating Temperature Range -20 → +70 °C
On back order for despatch 24/12/2019, delivery within 5 working days from despatch date.
Price (ex. GST) Each
$ 67.78
(exc. GST)
$ 77.95
(inc. GST)
units
Per unit
1 +
$67.78
Related Products
These surge protection devices are recommended for locations ...
Description:
These surge protection devices are recommended for locations having a high exposure to lightning, for example, light entrances to buildings protected by lightning rods or powered by aerial lines. These products are installed at the entrance of the installation (such ...
Acti 9 iPRD DIN rail Surge Protector Devices ...
Description:
Acti 9 iPRD DIN rail Surge Protector Devices are geared to absolute safety and improved continuity of service. Maximum discharge current 8 to 65 kA Integrated disconnector for short-circuit current withstand, Isc, up to 25 kAMaximum steady state voltage, Uc ...
Surge protection for the power supply with safe ...
Description:
Surge protection for the power supply with safe energy control. Varistor arrester free of leakage current. Extremely narrow design, just 12mm per position. Plug-in. Low voltage protection level of 1.5 kVOptical and mechanical status indicator.
Compact design with precise nominal current levels. Modular ...
Description:
Compact design with precise nominal current levels. Modular expansion possible thanks to the uniform, plug-in housing concept. Active current limitation, even when switching capacitive loadsN/O contact for remote signaling of the operating state.