Rechargeable Battery Module for use with UB

  • RS Stock No. 627-6219
  • Mfr. Part No. UZK12.071
  • Manufacturer PULS
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): CZ
Product Details

PULS Battery Module

The PULS 7Ah battery module utilizes a non-spillable, maintenance-free, VRLA, lead-acid battery. It is assembled in a package with all wiring and fusing included. The battery module is available in 2 different options. It can be ordered as a UZK-module with a battery or as a UZO-module without a battery that can be installed later to avoid outdated batteries. It has the input supply voltage of 12VDC. It is used with UB10.241 battery.

Features and Benefits

2 mounting options: DIN-rail or panel/wall mounting
30A Flat-blade fuse for short circuit protection
Current is 30A (discharging current) and 1.8A (charging current)
Easy access to the terminals and the fuse
heavy-duty fuse holder and spare fuse included
Small mounting footprint

Certifications

CULus approved
UL 60950-1 approved
CE certified
cCSAus certified
IECEx
GL Marine

Specifications
Attribute Value
Accessory Type Rechargeable Battery Module
For Use With UB
1 : Next working day
15 Within 5 working day(s) (Global stock)
Price (ex. GST) Each
$ 250.74
(exc. GST)
$ 288.35
(inc. GST)
units
Per unit
1 - 5
$250.74
6 - 11
$243.12
12 - 24
$238.01
25 - 59
$232.44
60 +
$227.42
Related Products
A safe redundant system is the result of ...
Description:
A safe redundant system is the result of the parallel connection of two power supply units which are decoupled from one another. To further increase system availability, TRIO DIODE provides the solution: decoupling with diode. Quick and easy installation, thanks ...
A safe redundant system is the result of ...
Description:
A safe redundant system is the result of the parallel connection of two power supply units which are decoupled from one another. To further increase system availability, UNO DIODE provides the solution: decoupling with diode. Quick and easy installation, thanks ...
Active redundancy module for superior system availability and ...
Description:
Active redundancy module for superior system availability and maximum operational reliability. QUINT S-ORING enables the separate structuring of a redundant system. In combination with the new QUINT POWER power supply, the redundant system is monitored continuously. Consistent redundancy up to ...
The PULS UF series buffer module has service ...
Description:
The PULS UF series buffer module has service free electrolytic capacitors. The Buffer units can be connected in parallel to increase the output capacity or the hold-up time. It is easy to install and does not need a control wiring. ...