XY2-CH Cable Switch, Straight, 15m, 2NC

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): MA
Product Details

Telemecanique XY2CH Emergency Stop Rope Pull Switches

The XY2-CH emergncy stop rope pull switch (also known as a grab wire switch) is ideal for applications such as conveyor systems, packaging, textiles, transfer machines, presses, woodworking equipment, paint lines and test laboratories.

For machine tools, conveyers & handling applications
Recommended distance between cable supports: 5m
Built-in turnbuckle accessory
Pushbutton reset
Water and dust tight enclosure
Surface mount

Note

Manufacturer part numbers with the suffix H29 are the ISO M20 threaded cable entry version.

Approvals

UL Listed file number: E164353 CCN NKCR. CSA certified file number: LR44087 class 3211 03. CE marked.

Specifications
Attribute Value
Range Preventa
Series XY2-CH
Reset Button Yes
Pole Configuration DP
Normal State Configuration 2NC
Mounting Orientation Straight
Maximum Rope Span 15m
Maximum Current 3 A ac, 270 mA dc
Maximum AC Voltage 240V
Maximum DC Voltage 250V
Number of Cable Entries 3
Conduit Entry M20 x 1.5
Size of Cable Entries M20 x 1.5
Depth 95mm
Minimum Operating Temperature -25°C
Dimensions 68 x 201 x 95 mm
E-Stop Button No
Maximum Operating Temperature +70°C
Length 68mm
IP Rating IP65
Width 201mm
9 : Next working day
16 Within 5 working day(s) (Global stock)
Price (ex. GST) Each
$ 340.03
(exc. GST)
$ 391.03
(inc. GST)
units
Per unit
1 - 2
$340.03
3 - 4
$297.54
5 +
$267.78
Related Products
Even under extreme conditions, such as major temperature ...
Description:
Even under extreme conditions, such as major temperature fluctuations, the SRM rope pull switch continues to work reliably. Rope pull switch manufactured in accordance with DIN EN 60947-5-5 and DIN EN ISO 13850Protection class IP67Stable and durable metal housing (aluminium ...
Maximum system length: 75 mSwitch function: 2 NC ...
Description:
Maximum system length: 75 mSwitch function: 2 NC + 2 NO (standard)Built-in reset buttonCable pull eyelet, low costVisualisation of correct cable tensionMeets EN418 and IEC947-5-5Protection class IP67.
Designed to offer grabwire switch protection for personnel ...
Description:
Designed to offer grabwire switch protection for personnel working in close proximity to conveyors or rotating and moving machines in various environmentsTypical applications: - conveyors, assembly lines, transfer lines, packaging machinery, process equipmentGrabwire switches are a convenient way of installing ...
Designed to offer grabwire switch protection for personnel ...
Description:
Designed to offer grabwire switch protection for personnel working in close proximity to conveyors or rotating and moving machinesTypical applications:- conveyors, assembly lines, transfer lines, packaging machinery, process equipmentDouble grabwire switches are a convenient way of installing two rope pull ...