Tektronix accessories include the industrial-style clamp-on current probes A621 ( 851-218 ) and A622 ( 851-224 ) which have mV outputs and enable current waveform measurements on all TekScopes.
The Tektronix long nose style clamp-on probe uses a Hall Effect current sensor to provide a voltage output to oscilloscopes. Equipped with a BNC connector, it can be used with a shrouded banana plug adapter*1. It can also be used on digital multimeters, TekMeter, and scopes. This device can measure AC/DC currents from 50mA to 100A peak over a frequency range of DC to 100kHz. It provides 10mV or 100mV output for each Amp measured.
For DMMs and oscilloscopes
Safety category voltage is 600V
Motor drives
Inverters
Power supplies
Avionics
CAT III 600V
CAT III
Attribute | Value |
---|---|
Current | 100A |
Probe Type | AC/DC |
Minimum Bandwidth | 0Hz |
Maximum Bandwidth | 100kHz |
Maximum Conductor Size | 11.8mm |
Safety Category | CAT III 600 V |
Safety Category Level | CAT III |
Model Number p | A622 |
Safety Category Voltage | 600V |
Bandwidth | DC → 100 kHz |