Pico Technology Oscilloscope Probe, Probe Type: Active, Differential 25MHz 700V

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): TW
Product Details

Pico 25MHz 700V Differential Probe TA041, 10:1/100:1

Pico TA041 is an active differential probe suitable for high common-mode voltage measurement applications up to ±700V (DC + peak AC). It can be used with signal speeds of up to 25MHz. This differential probe extends the functionality of standard single-ended input oscilloscopes to allow a safe and accurate method of making high-voltage differential measurements. Applications include making safe measurements in power circuit applications and acquisition of low-speed balanced differential signals found in serial communications buses.

Bandwidth DC to 25MHz (–3 dB)
Attenuation ratio 10:1/100:1
Accuracy ±2%
Input impedance 4MΩ ll 5.5pF each side to ground
Differential range (10:1) ±70V (DC + peak AC) or 70VRMS
Maximum differential (100:1) ±700V (DC + peak AC) or 700VRMS
Common mode range ±700V (DC + peak AC) or 700VRMS (10:1 & 100:1)
Absolute maximum voltage (differential or common mode) ±1400V (DC + peak AC) or 1000VRMS CATIII (10:1 & 100:1)
Swing ±7V into 2kΩ load
Offset (typical) <±5mV
Noise (typical) 0.7mVRMS
Source impedance (typical) 1Ω @ 1kHz, 8Ω @ 20kHz
CMRR (typical) 86dB @ 50Hz; 66dB @ 1MHz
Ambient operating temperature -10 to +40 °C
Ambient storage temperature -30 to +70°C
Ambient operating humidity 25 to 85% RH
Power requirement 4xAA cells or 6VDC/60mA mains adaptor or regulated 9VDC/40mA mains adaptor
Length of input leads 45cm
Length of BNC lead 95cm
Weight 400g
Dimensions 170 x 63 x 21 mm

Pico Technology Oscilloscope Probe

The Pico Technology TA041 oscilloscope probe is an active differential probe, suitable for high common-mode voltage measurement applications up to ±700V. It can be used with a signal speed of up to 25Hz. This differential probe extends the functionality of standard single-ended input oscilloscopes to allow a safe and accurate method of making high voltage differential measurements.

Features and Benefits

• Bandwidth is DC to 25MHz (–3dB)
• Attenuation ratio is 10:1/100:1
• Accuracy is ±2%
• Input impedance is 4Mohm ll5.5pF each side to ground
• Differential range is (10:1) ±70V (DC + peak AC) or 70VRMS
• Maximum differential is (100:1) ±700V (DC + peak AC) or 700VRMS
• Common mode range is ±700V (DC + peak AC) or 700VRMS (10:1 & 100:1)
• Absolute maximum voltage is ±1400V (DC + peak AC) or 1000VRMS (10:1 & 100:1)
• Swing is ±7V into 2kohm load
• Offset (typical) is <±5mV
• Noise (typical) is 0.7mVRMS
• Source impedance is 1ohm at 1kHz and 8ohm at 20kHz
• CMRR (typical) is 86dB at 50Hz and 66dB at 1MHz
• Ambient operating temperature ranges between -10°C and 40°C
• Power requirement 4xAA cells or 6VDC/60mA mains adaptor or regulated 9VDC/40mA mains adaptor

Applications

• Safe measurement in power circuit
• Acquisition of low speed balanced differential signals found in serial communications buses
• Transients in switching power supplies, inverters and motor drives, electronic ballasts and CRT displays
• Signals in the milliV range from sensors and other instrumentation

Certifications

• IEC-1010.1
• IEC-1010.2-031 CAT III
• Pollution Degree 2.

Specifications
Attribute Value
Probe Type Active, Differential
Attenuation 1:10, 1:100
Bandwidth 25MHz
Maximum Common Mode Input Voltage 700V
Number of Probes 2
Safety Category Level CAT III
Safety Category Voltage ±700 V, 700 Vrms
Safety Category CAT III ±700 V, 700 Vrms
19 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 939.57
(exc. GST)
$ 1,080.51
(inc. GST)
units
Per unit
1 +
$939.57
Related Products
The Tektronix current probes are created for the ...
Description:
The Tektronix current probes are created for the permanent or semi-permanent in-circuit installation. Each probe consists of a current transformer and an interconnecting cable. The current transformers have a small hole to pass a current-carrying conductor during circuit assembly. Approximate ...
Description:
Offering up to 200 MHz bandwidth and 1 GS/s sample rate, the MSO2000B Mixed Signal Oscilloscope Series from Tektronix delivers advanced debug features at an entry-level price. Users can quickly find and diagnose problems in complex designs with up to ...
MDO3000 oscilloscopes are designed to meet users' needs ...
Description:
MDO3000 oscilloscopes are designed to meet users' needs and aspirations now and into the future. Each model is multi-functional with integrated basic spectrum analyzer, Wave Inspector Navigation, MSO, serial and parallel bus triggering and analysis, and digital voltmeter. Optional instrument ...
One of the advantages of using Teledyne Le. ...
Description:
One of the advantages of using Teledyne Le. Croy oscilloscopes and probes is the large number of accessories available from RS for use with these instruments. It may be important to have up to four probes connected to tightly-packed test ...