4P 40 A, Instantaneous RCD Switch, Trip Sensitivity 30mA, DIN Rail Sentron 5SV3

  • RS Stock No. 124-7723
  • Mfr. Part No. 5SV3344-6KK12
  • Manufacturer Siemens
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

Series 5SV3 RCCBs

From Siemens the 5SV3 series are RCCBs suitable for personnel and fire protection. Available in 2 or 4 pole versions, each breaker can be DIN rail mounted. 5SV3 RCCBs offer highly reliable performance and excellent quality.

Residual current operated circuit breaker for personnel and fire protection
Silicone free
2 or 4 pole versions available
Instant tripping, surge current withstand capability >1kA
DIN rail mounting
Equipment life span: >10,000 switching cycles
Enclosure: IP20
Ambient temperature: -25→+45 °C
Break time - instantaneous
Protection against residual currents
Easy and safe installation

Specifications
Attribute Value
Number of Poles 3 + N
Current Rating 40 A
Trip Sensitivity 30mA
Rated AC Voltage 400 V
Mounting Style DIN Rail
Range Sentron
Break Time Instantaneous
Series 5SV3
Overall Length 71.8mm
Overall Width 77.2mm
Reset Actuator Type Toggle Switch
Tripping Characteristics Type A
Application Industrial, Non-Residential, Residential
Overall Dimensions 71.8 x 77.2 x 89.8mm
Overall Depth 89.8mm
Terminal Contact Type Screw
Circuit Breaker Type RCCB
3 Within 5 working day(s) (Global stock)
7 Within 7 working day(s) (Global stock)
Price (ex. GST) Each
Was $241.57
$ 198.32
(exc. GST)
$ 228.07
(inc. GST)
units
Per unit
1 +
$198.32
Related Products
These sense the relative humidity in an enclosure ...
Description:
These sense the relative humidity in an enclosure with electric/electronic components and turn on a heater at the set point, helping prevent the formation of condensation in the enclosure. The adjustment knob contains an LED which indicates when the connected ...
Ranges of power terminal blocks, fitted with 1 ...
Description:
Ranges of power terminal blocks, fitted with 1 or 2 covers, for DIN rail.A stopper, screw bridge bars and a branch for Faston 6.35 x 0.8mm tabs are available separately.Central hex socket connection screw, 6mm.M6 screw for direct fixing.
Introducing Eaton's range of PXF-A RCD, a professional ...
Description:
Introducing Eaton's range of PXF-A RCD, a professional and high-quality range of residual current devices. Providing complete protection, these RCD's have been created and designed to protect users from a fatal electric shock through the use of the automatic switch-off ...
This 2 / 4-pole RCD meets DIN VDE ...
Description:
This 2 / 4-pole RCD meets DIN VDE 0664 Part 1. It records AC and pulsating DC.Test symbols: VDE; ÖVE; SEV; CEBEC; SEMKO; NEMKO; DEMKO; FIMKO; KEMA.Un = 230 Vac with 2-pole,Un = 230 Vac / 400 Vac with 4-pole. ...