2P 40 A, Instantaneous RCD Switch, Trip Sensitivity 30mA, DIN Rail Sentron 5SV3

  • RS Stock No. 124-7730
  • Mfr. Part No. 5SV3314-6KK12
  • Manufacturer Siemens
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

Series 5SV3 RCCBs

From Siemens the 5SV3 series are RCCBs suitable for personnel and fire protection. Available in 2 or 4 pole versions, each breaker can be DIN rail mounted. 5SV3 RCCBs offer highly reliable performance and excellent quality.

Residual current operated circuit breaker for personnel and fire protection
Silicone free
2 or 4 pole versions available
Instant tripping, surge current withstand capability >1kA
DIN rail mounting
Equipment life span: >10,000 switching cycles
Enclosure: IP20
Ambient temperature: -25→+45 °C
Break time - instantaneous
Protection against residual currents
Easy and safe installation

Specifications
Attribute Value
Number of Poles 1 + N
Current Rating 40 A
Trip Sensitivity 30mA
Rated AC Voltage 230 V ac
Mounting Style DIN Rail
Range Sentron
Break Time Instantaneous
Series 5SV3
Overall Width 77.2mm
Reset Actuator Type Toggle Switch
Application Industrial, Non-Residential, Residential
Circuit Breaker Type RCCB
Terminal Contact Type Screw
Tripping Characteristics Type A
Overall Length 35.8mm
Overall Dimensions 35.8 x 77.2 x 89.8mm
Overall Depth 89.8mm
1 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 213.14
(exc. GST)
$ 245.11
(inc. GST)
units
Per unit
1 +
$213.14
Related Products
The Pfannenberg Din Rail Mount Mechanical Hygrostat has ...
Description:
The Pfannenberg Din Rail Mount Mechanical Hygrostat has activated control cabinet heaters or filter fans when a preset relative humidity is exceeded. This hygrostat unites thermostat and hygrostat in a single housing and at the same time monitors the relative ...
These sense the relative humidity in an enclosure ...
Description:
These sense the relative humidity in an enclosure with electric/electronic components and turn on a heater at the set point, helping prevent the formation of condensation in the enclosure. The adjustment knob contains an LED which indicates when the connected ...
EFL 012 Electronic Hygrostats will register the surrounding ...
Description:
EFL 012 Electronic Hygrostats will register the surrounding relative humidity and can switch a signal current using an internal relay. EFL 012 models can directly control signal processing devices. There is an LED integrated into the adjustment knob which shows ...
DIN rail mounting RCBOs from 6 to 40A ...
Description:
DIN rail mounting RCBOs from 6 to 40A with C tripping characteristics and positive indication with flag windows. Rated insulation voltage: 400VRated impulse withstand voltage: 4kVRated operating voltage: 230VResidual current off time ≤0.1s. Rated residual operating current: 30mA, 300mARated short-circuit ...