Product Details

SNV 4076SL Safety Relay with Timed Delay

Suitable for applications that require a safe timing sequence
Meet all requirements of the currently valid safety standards EN 62061, EN ISO 13849-1, Cat 4, SIL 3, PL e
Can be used as emergency stop and safety gate monitor
Single-channel or two-channel activation through contacts or semiconductors
Automatic and manual reset with reset button monitoring
3 immediate enables, 3 enables OFF-delayed, without re-triggering
Controlled stop and time monitored door lock
Cross monitoring

Specifications
Attribute Value
Supply Voltage 24 V dc
Number of Channels 2
Function Elevator System, Emergency Stop, Light Beam/Curtain, Safety Switch/Interlock
Safety Contacts 7
Range SafeRELAY
Reset Method Automatic, Manual, Monitored
Terminal Type Screw
Standards Met CCC, CPT, CULus, EN 50156-1, EN 62061, EN ISO 13849-1, FS, GL, GOST R, TUV
Width 114mm
Length 45mm
Depth 96.5mm
3 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 446.01
(exc. GST)
$ 512.91
(inc. GST)
units
Per unit
1 +
$446.01
Related Products
Safety relay for two-handed controlsDuring dangerous movements, the ...
Description:
Safety relay for two-handed controlsDuring dangerous movements, the relay requires the operator to keep both hands out of the danger zoneApplications: mechanical presses, hydraulic presses, safety control circuitsRemovable terminals with connection via spring terminalsDisplay LEDs for relay statusDIN rail ...
The advantages of using the UE403 in conjunction ...
Description:
The advantages of using the UE403 in conjunction with the M4000 series of light curtains are: local processing of signals (fewer cables, lower installation outlay, more control cabinet space); supply voltage for muting sensors direct from UE403; local IP65 connection ...
2 N/O instantaneous outputs provide stop category 0, ...
Description:
2 N/O instantaneous outputs provide stop category 0, 3 N/O timed contacts provide stop category 1 by allowing controlled deceleration of the motor until a complete stop is achieved4 solid state outputs for PLC signallingMonitored start button featureDelay time: 0 ...
Professional range of Schneider Preventa safety modules. The ...
Description:
Professional range of Schneider Preventa safety modules. The modules are designed for emergency stop, switch, sensing or safety light curtain monitoring. All models are highly reliable and excellent quality. IP20 Rated TerminalsIP40 Rated Enclosures.