Schneider Electric Configurable 24 V ac/dc Safety Relay Single or Dual Channel With 3 Safety Contacts

Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): ID
Product Details

Schneider Electric | Preventa XPSAF Series | Safety Relays

Simple and effective safety monitoring has never been more crucial in today's highly automated world. Prevention is key to site safety, that's why Schneider Electric offers a Safety Relay in the form of the 'Preventa XPSAF' module that is second to none. Being able to monitor faults with devices along a circuit has the power to stop emergency situations from even occurring.

Features and benefits:

• Single-channel with 3 N/O safety outputs

• Monitoring of a movable guard, with emergency stop monitoring 1 or 2 channel wiring usable.

• Configurable type of start is readily available for the type of activation you wish for your circuit.

• Monitoring of single safety functions, providing an automated solution for use with applications such as emergency push stop buttons or switches.

• Unlimited synchronisation between time inputs.

• Slin in design, with just 22.5mm of width meaning it can fit nicely even in space constraint spaces.

• Accepts cable up to 2.5mm²

• Symmetrical DIN rail support, offering flexible and versatile safety system installation.

• Local signalling in the form of LEDs.

Protection ratings & Safety features (see datasheet for specifics) -

• Impressive line resistance is available, varying between 90 to 100 Ohm (Ω).

• Input protection type is internal, electronic.

• EN1088/ISO 14119, EN 60204-1, EN/IEC 60947-5-1, EN/ISO 13850

• CSA, TUV & UL listed

• IP 40 (enclosure) for protection against small objects up to 1mm such as tools, wires and small wires.

• IP 20 (terminals) for protection against solid objects such as fingers, smaller tools up to 12mm.

• -25 to 60°C temperature range for operation, suitable in varying levels of heat/freezing temperatures.

Applications -

All dangerous machinery requires an automated solution to prevent harm to immediate users and also prevent damage to the machinery. Below are some of the safety applications

• Coded Magnetic Switch (CMS) to prevent tampering by unauthorised users.


• Time delay input if needed allowing you to set up your own time function.

• Light curtains / Two-hand control safety circuits

• Sensing mats and edges

Standards

IEC 204-1; EN 292; EN 418; EN 60204-1; EN 1088

Approvals

BG, UL, CSA

Specifications
Attribute Value
Supply Voltage 24 V ac/dc
Number of Channels 1, 2
Function Safety Switch/Interlock
Safety Contacts 3
Range Preventa
Terminal Type Screw
Depth 114mm
Length 99mm
Width 22.5mm
85 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 690.03
(exc. GST)
$ 793.53
(inc. GST)
units
Per unit
1 - 2
$690.03
3 - 4
$603.78
5 +
$543.42
Related Products
This can be quickly and reliably assembled to ...
Description:
This can be quickly and reliably assembled to form a tailor-made safety solution. To connect using TBUS correctly you will need one PSR-TBUS per module. For the last additional module use one PSR-TBUS-TP instead, this will close the feedback loop. ...
Suitable for applications that require a safe timing ...
Description:
Suitable for applications that require a safe timing sequenceMeet all requirements of the currently valid safety standards EN 62061, EN ISO 13849-1, Cat 4, SIL 3, PL eCan be used as emergency stop and safety gate monitorSingle-channel or two-channel activation ...
Stop-Category 0 acc. EN 60204-1Applications up to Category ...
Description:
Stop-Category 0 acc. EN 60204-1Applications up to Category 4 acc. EN 954-1, to SIL 3 according to EN62061 and PL e according to EN13849-1Can be used as emergency stop and safety gate monitorManual reset with self-monitoring on each ON-OFF cycleCross ...
Line fault detection on On-button:Manual restart or automatic ...
Description:
Line fault detection on On-button:Manual restart or automatic restartWith or without cross fault monitoring2-channelForcibly guided output contactsOutput: max. 4 NO instantaneous semiconductor monitoring outputLED indicator for operation, delay contacts and failureAs option with pluggable terminal blocks for easy ...