Schneider Electric Configurable 24 V ac/dc Safety Relay Single or Dual Channel With 3 Safety Contacts

Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): ID
Product Details

Schneider Electric | Preventa XPSAF Series | Safety Relays

Simple and effective safety monitoring has never been more crucial in today's highly automated world. Prevention is key to site safety, that's why Schneider Electric offers a Safety Relay in the form of the 'Preventa XPSAF' module that is second to none. Being able to monitor faults with devices along a circuit has the power to stop emergency situations from even occurring.

Features and benefits:

• Single-channel with 3 N/O safety outputs

• Monitoring of a movable guard, with emergency stop monitoring 1 or 2 channel wiring usable.

• Configurable type of start is readily available for the type of activation you wish for your circuit.

• Monitoring of single safety functions, providing an automated solution for use with applications such as emergency push stop buttons or switches.

• Unlimited synchronisation between time inputs.

• Slin in design, with just 22.5mm of width meaning it can fit nicely even in space constraint spaces.

• Accepts cable up to 2.5mm²

• Symmetrical DIN rail support, offering flexible and versatile safety system installation.

• Local signalling in the form of LEDs.

Protection ratings & Safety features (see datasheet for specifics) -

• Impressive line resistance is available, varying between 90 to 100 Ohm (Ω).

• Input protection type is internal, electronic.

• EN1088/ISO 14119, EN 60204-1, EN/IEC 60947-5-1, EN/ISO 13850

• CSA, TUV & UL listed

• IP 40 (enclosure) for protection against small objects up to 1mm such as tools, wires and small wires.

• IP 20 (terminals) for protection against solid objects such as fingers, smaller tools up to 12mm.

• -25 to 60°C temperature range for operation, suitable in varying levels of heat/freezing temperatures.

Applications -

All dangerous machinery requires an automated solution to prevent harm to immediate users and also prevent damage to the machinery. Below are some of the safety applications

• Coded Magnetic Switch (CMS) to prevent tampering by unauthorised users.


• Time delay input if needed allowing you to set up your own time function.

• Light curtains / Two-hand control safety circuits

• Sensing mats and edges

Standards

IEC 204-1; EN 292; EN 418; EN 60204-1; EN 1088

Approvals

BG, UL, CSA

//media.rs-online.com/t_line/LI360435-01.gif
Specifications
Attribute Value
Supply Voltage 24 V ac/dc
Number of Channels 1, 2
Function Safety Switch/Interlock
Safety Contacts 3
Range Preventa
Terminal Type Screw
Depth 114mm
Length 99mm
Width 22.5mm
37 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 390.56
(exc. GST)
$ 449.14
(inc. GST)
units
Per unit
1 - 2
$390.56
3 - 4
$356.38
5 +
$331.44
Related Products
The Phoenix Contact 2700525 safety relay is designed ...
Description:
The Phoenix Contact 2700525 safety relay is designed for emergency stop (E-Stop), light grids and safety doors up to Cat.4/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061With 3 enabling current path and 1 signalling current path ...
The BG5924 is a highly compact safety switch ...
Description:
The BG5924 is a highly compact safety switch device for the construction of emergency stop switches. It serves to protect personnel and machines in accordance with the EC directive for machines 89/392/EEC, IEC 204-1, EN 60204-1, DIN VDE 0113-1. Single-channel ...
The UE48 safety relay is suitable for interfacing ...
Description:
The UE48 safety relay is suitable for interfacing SICK light curtains and laser scanner products (S3000, C4000 and M4000). Cross circuit on dual channel wired systems. Restart interlock. External device monitoring. Synchronous time monitoring. Manual and automatic reset3 LEDs: supply ...
Emergency stop relay compliant with the EC Directive ...
Description:
Emergency stop relay compliant with the EC Directive on machines 98/37/EC1-channel configurationLED status display. Short circuit detection between terminal Y1 and earth. Overall width of 22.5 mm.