Sick 24 V dc Safety Relay Single or Dual Channel With 3 Safety Contacts Compatible With Light Beam/Curtain

  • RS Stock No. 701-9212
  • Mfr. Part No. UE10-2FG2D0
  • Manufacturer Sick
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

UE10 and UE12, Dual Channel

Safety relay suitable for use with safety laser scanners and safety light curtains. The UE12-2FG2DO (stock number 701-9216) can have the number of outputs increased with the cascading jumper that is supplied with it

NC contact for external device monitoring (EDM)
2 LEDs
Maximum power consumption DC: 3.2 W
Rated operating current (voltage): 3 A (230Vac), 4 A (24Vdc)
Maximum switching current: 6 A
B10d parameter: 400000
TM (Mission Time): 20 a
SIL3 (IEC 61508), SILCL3 (IEC 62061), Category 4 (EN 954-1), same as protective device, PL e (EN ISO 13849)

Note

Stock mumber 701-9216 is supplied with a cascading jumper.

Specifications
Attribute Value
Supply Voltage 24 V dc
Number of Channels 1, 2
Function Light Beam/Curtain
Safety Contacts 3
Terminal Type Screw
Length 89.8mm
Depth 70.8mm
Width 17.8mm
102 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 159.50
(exc. GST)
$ 183.42
(inc. GST)
units
Per unit
1 +
$159.50
Related Products
"Safety features The safety relay meets the following ...
Description:
"Safety features The safety relay meets the following safety requirements The circuit is internally redundant with built-in self-monitoring. The safety device remains effective in the case of a component failure. The correct opening and closing of the safety device relays ...
"Safety features The safety relay meets the following ...
Description:
"Safety features The safety relay meets the following safety requirements The circuit is internally redundant with built-in self-monitoring. The safety device remains effective in the case of a component failure. The correct opening and closing of the safety device relays ...
"Safety features The safety relay meets the following ...
Description:
"Safety features The safety relay meets the following safety requirements The circuit is internally redundant with built-in self-monitoring. The safety device remains effective in the case of a component failure. The correct opening and closing of the safety device relays ...
"Safety features The safety relay meets the following ...
Description: