Omron 24 V ac/dc Safety Relay Dual Channel With 3 Safety Contacts and 1 Auxilary Contact Compatible With Emergency Stop

  • RS Stock No. 757-9304
  • Mfr. Part No. G9SB-3012-A AC/DC24
  • Manufacturer Omron
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): CN
Product Details

G9SB, Safety Relays, Ultra Slim

The Omron G9SB series is an ultra slim safety relay available in either a 17.5mm or 22.5mm housing. The 17.5mm units have 2 or 3 safety contacts and the 22.5mm units have 3 safety contacts and an auxiliary contact.

1 and 2 input channel units
Manual and automatic reset units
Certification up to category 4 according to EN954-1 (depending on the application)
Can also be used with safety sensors F3SN, F3SH, F3S-B, F3STGR, F3SL, F3S-J
Conforms to EN standards (TUV approval)

Note

When ordering take note of the safety reset mode that is required: Models G9SB**A and G9SB ** B = Auto Reset operation; Models G9SB ** D = Manual Reset operation

Approvals

EN954-1, EN60204-1, UL508, CSA C22.2 No. 14

G9SB Ultra Slim Safety Relays.

• Ultra slim relay module.
• Models with a width of 17.5 mm are available with 2 or 3 poles (safety contacts).
• Models with a width of 22.5 mm with 3 poles (safety contacts).
• 1 and 2 input channels.
• Manual and automatic reset.
• Can be DIN rail mounted.
• Relays with inverse inputs are used when inputting signals from 2 mechanical switches.
• Relays with positive commons are used when inputting signals from a safety sensor or one mechanical switch.
• Conform to EN standards (TUV approval).
• G9SB-3010 is applied to safety category 3 of EN 954-1 if double breaking is used.

Applicable to Safety Sensors.

• Model F3S-B
• Model F3SH
• Model F3S-J
• Model F3SL
• Model F3SN
• Model F3S-TGR Model F3S-TGR Safety Sensors covers a range of articles available within Non-Contact Safety Switches, Light Curtains, Light Beams and Machine Guarding Accessories.

G9SB-3012-A AC/DC24 Slim Safety Relay.

• Main contact 3PST-NO (normally open).
• Auxiliary contact SPST-NC (normally closed).
• 2 Input channels
• Auto-reset.
• Input type Inverse.
• Rated voltage 24 V ac/dc.
• Operating voltage range 85% to 110% of the rated power supply voltage.
• Power consumption 2 VA/1.7 W max.
• Input current 30 mA max.
• Resistive load
• Rated load 250 V ac, 5 A. 30 V dc, 5 A.
• Rated carry current 5 A.

Features and Benefits.

• Contact resistance 100 mΩ
• Insulation resistance 100 MΩ mon (at 500 V dc)
• Vibration resistance 10 to 55 to 10 Hz, 0.375 mm single amplitude (0.75 mm double amplitude)
• Shock resistance destruction 300 m/s².
• Shock resistance malfunction 100 m/s²
• Failure rate (P Level) (reference value) 5 V dc, 1 mA
• Always turn OFF the G9SB before connecting an expansion unit.
• If mounting multiple units next to each other the rated current will be 3 A. (do not apply any higher currents)
• Stranded wire 0.2 to 2.5 mm²
• Solid Wire 0.2 to 2.5 mm²
• Screw torque of 0.5 to 0.6 Nm. (incorrect screw tightening can result in a malfunction or generate heat).
• Positive thermistor built onto the circuits detecting short breakdowns.
• Weight 120 g

Applications Include.

• Light curtain.
• Light guard.

Specifications
Attribute Value
Supply Voltage 24 V ac/dc
Number of Channels 2
Auxiliary Contacts 1
Function Emergency Stop
Safety Contacts 3
Depth 112mm
Width 23mm
Length 100mm
3 : Next working day
29 Within 5 working day(s) (Global stock)
Price (ex. GST) Each
$ 275.60
(exc. GST)
$ 316.94
(inc. GST)
units
Per unit
1 - 2
$275.60
3 - 4
$241.14
5 +
$217.03
Related Products
This is the main module in the UE410 ...
Description:
This is the main module in the UE410 FLEXI system. 8 available programs can be set using rotary switches (e.g. emergency stop pushbuttons, Type IIIA and IIIC two-hand controls, safety interlock switches, non-contact switches, testable Type 2 sensors, hold to ...
The BG5924 is a highly compact safety switch ...
Description:
The BG5924 is a highly compact safety switch device for the construction of emergency stop switches. It serves to protect personnel and machines in accordance with the EC directive for machines 89/392/EEC, IEC 204-1, EN 60204-1, DIN VDE 0113-1. Single-channel ...
Safety category 4 in accordance with DIN EN ...
Description:
Safety category 4 in accordance with DIN EN 954Output: 2 N/Os, 1 N/C1 or 2-channel configuration. Line termination detection on the ON button. Programmable: Activation via the ON button or automatic ON function when the operating voltage is applied. Programmable: ...
Simple and effective safety monitoring has never been ...
Description:
Simple and effective safety monitoring has never been more crucial in today's highly automated world. Prevention is key to site safety, that's why Schneider Electric offers a Safety Relay in the form of the 'Preventa XPSAF' module that is second ...