Wieland 24 V dc Safety Relay Dual Channel With 2 Safety Contacts

  • RS Stock No. 780-5098
  • Mfr. Part No. R1.188.3700.0 - SNZ1022K-A
  • Manufacturer Wieland
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

Wieland SNZ 1022K Safety Relay

SNZ 1022K Safety Relay Function - after the power supply is established at terminals A1/A2 and the feedback loop is closed (terminals Y1/Y2), the release current paths are closed when the actuators (S1+S2) are operated at the same time. The two actuators must be operated within 0.5 s to trigger a release. If just one of the two actuators is released, the device is immediately de-energized and the enabling current path is opened. The device can only be restarted once the two actuators are returned to their initial positions (e.g. the two-hand buttons have been released). The current status of the device is shown by 2 LEDs. The presence of the power supply is indicated with the SUPPLY LED, the operation of the two actuators with the K1 LED, if there is synchronous operation.

Monitoring of Safety Gate and Two Hand Control applications
Stop Category 0 according to EN 60204-1
Two-channel actuation; 1 NO contact and 1 NC contact for each channel
Cross monitoring
Monitoring of synchronous activation
1 changeover contact
Screw terminals, pluggable
Up to PL c / Category 1 (EN ISO 13849-1)
Up to SILCL 1 (EN 62061)

Specifications
Attribute Value
Supply Voltage 24 V dc
Number of Channels 2
Safety Contacts 2
Range SafeRELAY
Terminal Type Screw
3 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 172.62
(exc. GST)
$ 198.51
(inc. GST)
units
Per unit
1 +
$172.62
Related Products
Detects the stop condition of all types of ...
Description:
Detects the stop condition of all types of AC or DC motor driven machines which, when the motor runs down, produce a residual voltage in the windings. No additional sensor is required1 N/O and 1 N/C contacts, EN954-1 Category 3 ...
2 N/O instantaneous outputs provide stop category 0, ...
Description:
2 N/O instantaneous outputs provide stop category 0, 3 N/O timed contacts provide stop category 1 by allowing controlled deceleration of the motor until a complete stop is achieved4 solid state outputs for PLC signallingMonitored start button featureDelay time: 0 ...
Protection of humans and machines in accordance with: ...
Description:
Protection of humans and machines in accordance with: EC Directive on Machines 89/392/EEC, IEC 204, EN 60204, DIN VDE 0113. Machine emergency stop switchesMonitoring sliding grill guardsSK 4 (with equivalent switching)Output: 2 N/Os for AC 250 V1 or 2-channel configurationLine ...
Single or dual channel cabling with short-circuit detectionChoice ...
Description:
Single or dual channel cabling with short-circuit detectionChoice of self-monitoring or automatic resetDisplay LEDs for status of channels 1 and 2, input circuits, power supply voltage and resetReturn loop for monitoring external contactors2 solid state outputs.