Weidmuller Temperature → Current Signal Conditioner, Temperature 0 → 100 °C Input

  • RS Stock No. 393-0235
  • Mfr. Part No. MCZ PT100/3 CLP 0...100C -8425720000
  • Manufacturer Weidmuller
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
Product Details

Temperature Controller for Pt100 (IEC 751)

Weidmuller MCZ series RTD signal converter in terminal design. Suitable for the connection of 2 and 3 wire PT100 sensors with a current loop 4 ... 20 mA signal on the output side.

Mini set-point controller in terminal design
Tension clamp connection
1 module width (6mm)
DIN Rail mount

Specifications
Attribute Value
Input Type Temperature
Output Type Current
Signal Conditioner Type Temperature → Current
Input Range 0 → 100 °C
Output Range 4 → 20 mA
Supply Voltage 30 V
Mounting Type DIN Rail
Sensor Compatibility RTD
Minimum Operating Temperature -25°C
Maximum Operating Temperature +50°C
Operating Temperature Range -25 → +50 °C
14 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 202.55
(exc. GST)
$ 232.93
(inc. GST)
units
Per unit
1 +
$202.55
Related Products
EYC-Tech DPT02 series digital universal input signal converters ...
Description:
EYC-Tech DPT02 series digital universal input signal converters measure a wide range of input types and convert these into an analogue output. The DPT02 features a 3-digit readout display and simple keypad for programming the signal output and scale. 3-digit ...
Switches on if over/under limits or if device ...
Description:
Switches on if over/under limits or if device is idleAdjustable thresholds: 0.1 Hz → 25 kHzDC Version: IFMR0036 (9 → 32 VDC)AC Version: IFMR0066 (85 → 250 VAC)All sensors are adjustable via DIP switchStatus display via 2 Info LEDsEasy assembly ...
Single channel signal processors for use with insertion ...
Description:
Single channel signal processors for use with insertion flow sensors that do not have internal control logic options available with digital or analogue output. Finger protectionLED indication of flow conditionsSimple switch point set up using potentiometers500Ω load (max.)PNP Output8-pole, 18mm ...
Various additional functions can be realised effortlessly with ...
Description:
Various additional functions can be realised effortlessly with the signal adapters.Output signals or counting and timer functions can be changed without additional installations.The signal adapter is plugged in easily between the standardised M12 ports of the sensor and connection lead.It ...