RS PRO Analogue → Relay Signal Conditioner, Analogue

  • RS Stock No. 466-2400
  • Manufacturer RS PRO
Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): GB
Product Details

BD120 Dual Level Trip Amplifier

RS Pro dual level trip amplifiers operate from a single process input, with a dual trip action. This output can be arranged so that the alarm condition is triggered either above or below the defined set point. The relay can also be configured for a Fail-Safe (energised in the stable state to de-energise in the alarm state) or Non-Fail Safe (de-energised in the stable state to energise in the alarm state) operation.

2 x SPCO relay (max. 60W load) output
High trip/low trip (user-configurable); fail-safe design (HLFS)
Adjustable set points
Bi-colour LED trip status indication: Green LED indicates stable state; red LED indicates alarm state

Specifications
Attribute Value
Input Type Analogue
Output Type Relay
Signal Conditioner Type Analogue → Relay
Input Range -250 → +250 V dc, 0 → 20 mA, 0 → 250 V ac
Supply Voltage 230 V ac
Mounting Type DIN Rail
Sensor Compatibility RTD, Thermocouple
Minimum Operating Temperature 0°C
Maximum Operating Temperature +45°C
Operating Temperature Range 0 → +45 °C
Termination Screw
Module Type Amplifier
3 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 316.59
(exc. GST)
$ 364.08
(inc. GST)
units
Per unit
1 +
$316.59
Related Products
Wago 857 series JUMPFLEX millivolt signal conditioner converts ...
Description:
Wago 857 series JUMPFLEX millivolt signal conditioner converts input millivolt signals into an analogue standard signal on the output side. PC configuration interface Switching between measurement ranges is calibrated Clipping capability allows analogue signal limitation to output end values Safe ...
The MTL5582 connects to a resistance temperature device ...
Description:
The MTL5582 connects to a resistance temperature device (RTD) or other resistance located in a hazardous area, isolatesit and repeats the resistance to a monitoring system in the safe area. One channelConnecting from 2-, 3- or 4-wire RTDsSelection with a ...
The MTLx581 takes a low-level dc signal from ...
Description:
The MTLx581 takes a low-level dc signal from a voltage source in a hazardous area, isolates it, and passes it to a receiving instrument located in the safe area. The module is intended for use with thermocouples utilising external cold-junction ...
The MTLx532 isolates pulses from a switch, proximity ...
Description: