PR Electronics 5116A, Analogue to Current Signal Conditioner, Analogue

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DK
Product Details

5116A Type - Programmable Transmitter

5116A programmable transmitter are for linearizing electronic temperature measurement. Also for the conversion of linear resistance variation e.g, from solenoids and butterfly valves or linear movements with attached potentiometer.

Input for RTD, TC, mV, Ohm, potentiometer, mA and V
2-wire supply < 16.5 V
Bipolar voltage input
Input can be calibrated to the exact span of the process
Zero drift on the process signal can be adjusted by a single press of the front buttton
Output for current, voltage and 2 relays
Green front LED indicates normal operation and malfunction
Yellow LED is ON for each active output relay
Continuous check of vital stored data for safety reasons
3-port 3.75 kVAC galvanic isolation
Universal supply by AC or DC
Power supply and signal isolator for 2-wire transmitters

PR Electronics DIN Rail Mounting

Specifications
Attribute Value
Input Type Analogue
Output Type Current
Signal Conditioner Type Analogue to Current
Input Range 0 → 100 mA, 0 → 250 V dc, 10 MΩ, 10 Ω
Output Range 0 → 20 mA
Supply Voltage 19.2 → 300 V dc, 21.6 → 253 V ac
Mounting Type DIN Rail
Sensor Compatibility Linear Resistance, Potentiometer, RTD, Thermocouple
Minimum Operating Temperature -20°C
Maximum Operating Temperature +60°C
Series 5116A
Operating Temperature Range -20 → +60 °C
2 Within 5 working day(s) (Global stock)
5 Within 5 working day(s) (Global stock)
Price (ex. GST) Each
$ 864.64
(exc. GST)
$ 994.34
(inc. GST)
units
Per unit
1 +
$864.64
Related Products
Range of 5700 series Multi-functional Panel Meters are ...
Description:
Range of 5700 series Multi-functional Panel Meters are characterized by their flexibility and stability. The panel meters meet nearly every demand for display readout of process signals, and have universal input and supply capabilities.They provide a real-time measurement of your ...
5106A HART transparent repeater processes current signals of ...
Description:
5106A HART transparent repeater processes current signals of 4…20 mA and is based on microprocessor technology for gain and offset. The analogue signal is transmitted at a response time of less than 25 ms. 1 (136-8689) or 2 (136-8690) channel ...
5223A Programmable converter has an f/l function that ...
Description:
5223A Programmable converter has an f/l function that performs frequency to current and voltage conversion and an f/f function for pulse division or multiplication. The f/f function also works as a buffer, collecting fast pulse trains. Pulse calculatorFrequency generator (used ...
Single channel signal processors for use with insertion ...
Description:
Single channel signal processors for use with insertion flow sensors that do not have internal control logic options available with digital or analogue output. Finger protectionLED indication of flow conditionsSimple switch point set up using potentiometers500Ω load (max.)PNP Output8-pole, 18mm ...