Weidmuller ACT20X, NAMUR Sensor to NPN Signal Conditioner, NAMUR Sensor IECEx, 8 V dc Input, <2.5 V dc Output

  • RS Stock No. 902-8000
  • Mfr. Part No. 8965360000
  • Manufacturer Weidmuller
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DK
Product Details

ACT20X HDI-SDO-S/2HDI-2SDO-S Signal Isolating Converter

The ACT20X HDI-SDO-S/2HDI-2SDO-S isolating converters are specially designed for recording NAMUR sensor signals and digital switching signals which originate from Ex zone 0. Negative-switching (NPN) transitor outputs are used to transmit the signals to applications in the safe zone.

DIN Rail mounting
22.5 mm width
Alarm contact in the event of a malfunction
1 or 2 channel options
Screw connection, removable terminal block
IP20 protection

Specifications
Attribute Value
Input Range 8 V dc
Output Range <2.5 V dc
Supply Voltage 19.2 → 31.2 V
Mounting Type DIN Rail
Minimum Operating Temperature -20°C
Maximum Operating Temperature +60°C
Standards Met CE, CUL, EAC, Ex, GOSTEX, RoHS, TUV
Series ACT20X
Interface USB Cable
Termination Screw
Operating Temperature Range -20 → +60 °C
Number of Channels 1
Hazardous Area Certification IECEx
1 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 452.71
(exc. GST)
$ 520.62
(inc. GST)
units
Per unit
1 +
$452.71
Related Products
The Festo SDE5 series pressure sensor is designed ...
Description:
The Festo SDE5 series pressure sensor is designed to monitor pressure of compressed air. It works on 30V supply voltage. The sensor measures the pressure in the range of -1bar to 0bar. It has a normally open (NO) contact and ...
Murr. Elektronik MAK 12.4 series voltage comparrator is ...
Description:
Murr. Elektronik MAK 12.4 series voltage comparrator is designed for evaluating analog voltages, generated by pressure, temperature or other sensors. The analog input values are compared to internal or external reference voltages to over or underflow. Outputs will be switched, ...
Switches on if over/under limits or if device ...
Description:
Switches on if over/under limits or if device is idle. Adjustable thresholds: 0.1 Hz → 25 k. HzDC Version: IFMR0036 (9 → 32 VDC)AC Version: IFMR0066 (85 → 250 VAC)All sensors are adjustable via DIP switch. Status display via 2 ...
Galvanic isolation output to supply. Pt100 2 or ...
Description:
Galvanic isolation output to supply. Pt100 2 or 3-wire operation. Selectable input sensor temperature range: -50 to +100°C or -50 to +300°COutput selectable via terminals: 0 to 10V, 0 to 20mA or 4 to 20mAOffset and gain adjustable via front ...