Weidmuller ACT20X, NAMUR Sensor to Current Signal Conditioner, NAMUR Sensor IECEx, 8 V dc Input, 2 A Output

  • RS Stock No. 902-8013
  • Mfr. Part No. 8965380000
  • Manufacturer Weidmuller
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DK
Product Details

ACT20X 2HDI-2SDO-RNC-S Signal Isolating Converter

The ACT20X 2HDI-2SDO-RNC-S isolating converters are specifically designed for recording NAMUR sensor signals and digital switching signals, which originate from Ex zone 0. With 11 mm width per channel, these devices need little space in the electrical cabinet.

DIN Rail mounting
22.5 mm width
2 channels
NO or NC contact options available
Alarm contacts in the event of a malfunction
Screw connections, removable terminal block
IP20 protection

Specifications
Attribute Value
Input Range 8 V dc
Output Range 2 A
Supply Voltage 19.2 → 31.2 V
Mounting Type DIN Rail
Minimum Operating Temperature -20°C
Maximum Operating Temperature +60°C
Termination Screw
Standards Met CE, CUL, EAC, Ex, GOSTEX, RoHS, TUV
Series ACT20X
Number of Channels 2
Operating Temperature Range -20 → +60 °C
Hazardous Area Certification IECEx
Interface USB Cable
2 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 364.63
(exc. GST)
$ 419.32
(inc. GST)
units
Per unit
1 +
$364.63
Related Products
Switches on if over/under limits or if device ...
Description:
Switches on if over/under limits or if device is idle. Adjustable thresholds: 0.1 Hz → 25 k. HzDC Version: IFMR0036 (9 → 32 VDC)AC Version: IFMR0066 (85 → 250 VAC)All sensors are adjustable via DIP switch. Status display via 2 ...
From Phoneix Contacts, the DIN-Rail mounted MCR-C 3-way ...
Description:
From Phoneix Contacts, the DIN-Rail mounted MCR-C 3-way signal conditioners are used for electrical isolation and conversion of analogue signals. Three-way electrical isolation ensures reliable decoupling of the sensor circuit from the processing circuit, thus also preventing several distributed measurement ...
Galvanic isolation output to supply. Pt100 2 or ...
Description:
Galvanic isolation output to supply. Pt100 2 or 3-wire operation. Selectable input sensor temperature range: -50 to +100°C or -50 to +300°COutput selectable via terminals: 0 to 10V, 0 to 20mA or 4 to 20mAOffset and gain adjustable via front ...
Monitoring or control of temperature - 50°C to ...
Description:
Monitoring or control of temperature - 50°C to +300°C in 5 ranges. Compensated 3-wire PT100 sensor operation. Adjustable setpoint. Hysteresis adjustable ±0.5 to 20% of selected range. Inversion of the relay contact function - heating/cooling control0-10V analogue outputs for both ...