Red Spot™ Range, Type T HBC
As the fuse allows for the starting surge of a motor its full load current must not exceed the lesser of the dual current rating. e.g. 20 M25 must not have a continuous load of greater than 20A
Features and Benefits
Breaking capacity 80kA ac 40kAdc
Rated up to 550Vac/ 250Vdc (Type A1) & 660Vac/ 460Vdc (Type A2)
General purpose (gG) and dual motor rated (gM) types
Low power dissipation
660Vac rated (A1 types 415Vac)
ASTA 20 certified
Rated up to 550Vac/ 250Vdc (Type A1) & 660Vac/ 460Vdc (Type A2)
General purpose (gG) and dual motor rated (gM) types
Low power dissipation
660Vac rated (A1 types 415Vac)
ASTA 20 certified
As the fuse allows for the starting surge of a motor its full load current must not exceed the lesser of the dual current rating. e.g. 20 M25 must not have a continuous load of greater than 20A.
Eaton British Standard Fuse, A1 Size, 2A - NIT2
Keep your circuits safe from damage and hazards with this British Standard fuse from Eaton. The fuse features metal slotted tags that extend off the ends of its body to connect it to a fuse holder. When too much electricity goes through, the metal strip inside it melts, breaking the circuit and ensuring safety. The device has HRC (high-rupture capacity) so the strip wont melt away until the current overload reaches a sustained or dangerous level. You'll find this fuse used in general-purpose rating (gG) and dual-motor rating (gM) motor protection devices.
Features & Benefits
Bolted metal tag design slots securely onto a fuse holder for fast, easy attachment to your circuit
Sensitive 2A (amperes) current rating for use with low-powered circuits
Low power dissipation prevents large amounts of circuit power loss as the current passes through the fuse
Sensitive 2A (amperes) current rating for use with low-powered circuits
Low power dissipation prevents large amounts of circuit power loss as the current passes through the fuse
What's the breaking capacity of this British Standard fuse?
This British Standard fuse has a breaking capacity of 80kA (kiloamperes), ensuring that the device can safely stop currents even if power from the circuit increases well above the fuse rating. This helps to prevent fires and electric shocks.
Note
Eaton formerly known as Bussmann
Specifications
Attribute | Value |
---|---|
Current Rating | 2A |
Fuse Size | A1 |
Voltage Rating | 550V ac |
Fuse Standard | BS 88-2:1988, IEC 60269-2 |
Fixing Centres | 44.5mm |
Application Category | gG, gM |
Tag Width | 11.1mm |
Fuse Speed | T |
High Rupture Capacity | Yes |
Overall Length | 55.6mm |
Tag Type | Slotted |
Body Diameter | 14.1mm |
Tag Orientation | Offset |
Body Height | 36.5mm |
Series | Bussmann |