Burkert Solenoid Valve 143490, 2 port , NO, 230 V ac, 1/2in

  • RS Stock No. 337-5537
  • Mfr. Part No. 143490
  • Manufacturer Burkert
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

Burkert Solenoid Valve

The Burkert 0280 series 1/2inG female solenoid valve has a supply voltage of 230VAC. This 2-port NO position valve with a servo diaphragm has a compact design with NBR seal. The valve is normally open by spring action assisted by the fluid pressure. When de-energized, the media is exhausted to atmosphere via the pilot operator. When energized, the space above the servo diaphragm is exhausted via the pilot valve, the diaphragm is lifted by the fluid pressure to close the valve.
Compact solenoid valves suitable for most gas and fluid handling applications. Where practical, valves are shown with a schematic diagram showing the (circuit) function. The diagram is laid out so that the left-hand side of the diagram describes the operation of the valve when the coil is energised. When the coil is de-energised, the spring (or servo-assist) return controls the valve and is described on the right-hand side of the diagram. The 3 / 2-way designation indicates a valve with three ports and two modes of operation. It is normal practice to refer to 2 / 2-way valves as two ways. The port designations A, B, P, P1, P2 and R are used on the schematic diagrams and are marked on the valve bodies. Valve bodies are marked for a specific circuit function but can often be used for other functions. Reference to the schematic diagrams and technical specifications indicates the appropriate connections and pressure capabilities when an alternative circuit function is required.

Features and Benefits

Maximum working pressure is 16bar
Flow factor(Kv) is 1m³/h
High flow rate
Operating temperature is between -10°C and 55°C
Power consumption is 21VA(inrush)
Solenoid epoxy encapsulation efficiently dissipates the heat generated by the coil
The supply voltage is 230VAC

Applications

Circuit function B for air or gases (consult for use with liquids)
Fire protection installations
Irrigation systems
Laundries
Machine tools
Neutral gases and liquids
Sanitary applications
Varnishing technology

Certifications

IP65 rated

Specifications
Attribute Value
Supply Voltage 230 V ac
Number of Ports 2
Connection 1/2 in G Female
Connection Size 1/2in
Default Valve Position NO
Suitable Applications Compressed Air, Gas, Hydraulic Oil, Neutral Liquid
Type 2/2
Orifice Diameter 8mm
Body Material Brass
Maximum Working Pressure 16 bar
Operating Temperature Range -10 → +55 °C
Minimum Operating Temperature -10°C
Maximum Operating Temperature +55°C
Flow Factor Kv 1m³/h
Connection Gender Female
Series 0280
Thread Standard or Connection Type G
Temporarily out of stock - back order for despatch when stock is available
Price (ex. GST) Each
$ 92.48
(exc. GST)
$ 106.35
(inc. GST)
units
Per unit
1 - 4
$92.48
5 - 9
$90.86
10 +
$89.18
Related Products
Internal timers can be adjusted after the supply ...
Description:
Internal timers can be adjusted after the supply is isolated without removing the unit. Robust polyamide construction to DIN 43650For controlling RS solenoid valves and others with the same type of termination. Protected to IP65User programmable via built-in DIP switches ...
The SMC VX3000 series is a direct acting, ...
Description:
The SMC VX3000 series is a direct acting, 3 port solenoid valve. Suited to various applications such as air, oil, water and steam. Valves are easily replaced without changing existing piping. DIN electrical connection. Class B & Class H coil ...
Easy electrical installation by means of a screw ...
Description:
Easy electrical installation by means of a screw terminal coil. Enclosure provided with a 1/2 NPT threaded entry hole (M20 x 1,5 in option) for a broad range of cable entriesA wide range of valves can be supplied with the ...
Direct-acting, rigid PVC bodied valves for use with ...
Description:
Direct-acting, rigid PVC bodied valves for use with aggressive gases and liquids, bases and acids up to a medium concentration. Separate diaphragm isolates the actuator from the fluid. Insensitive to contaminated fluids, except sharp solid and long fibres. No differential ...