United Automation, PFC2 100KVR, Power Factor Switch, 150A, 5.6kg, 270 x 250 x 130mm

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
Product Details

PFC2 80/100kVAR Power Factor Switches

The PFC2 controllers are suitable for 3-wire, 3-phase floating-star or closed-delta configured capacitive loads for Power Factor Correction and can be used in capacitor banks with or without chokes fitted. They are designed to dramatically reduce the inrush current normally found with contactor-based systems and could be used in situations where rapid changes in Power Factor occur such as welding plants, lifts, cranes and wind-powered plants.

Current rating: 125A (80kVAR), 150A (100kVAR) @ 415Vrms
Input voltage: 415Vrms ±10%
Frequency: 50/60Hz
Control signal input: +8 to +24Vdc, Common 0V or Common +VE, Open Collector or Volt Free Contact
Alarm relay functions: Voltage free alarm relay is rated for 125Vac @ 2A.
LED indicators: Green = DC Power ON, Red = Fault, Orange = Signal enabled, Red/Orange = Capacitors discharging
Cooling fan: +24Vdc
Fan ’switch-on’: Typically +55ºC
Over Temperature: Trip in temperature: +90ºC ±1ºC (Status LED indicator ’flashes’ with ON/OFF rapid pulsing
Trip out temperature: +85ºC ±1ºC
Phase loss detection: Phase loss or Fuse failure orange and red LEDs flash alternately
Status LED Fault condition: Status LED indicator ’flashes’ ON/OFF continuously at 1.5 second intervals
Sensor loss detection: Status LED indicator ’flashes’ ON/OFF continuously in equal intervals
Power cable terminations: Supply, Load & Earth 35mm² rising clamp terminal block
Terminal torque settings: 3.2Nm min (35mm²) Power terminals only
Signal cable terminations: Remote supply Auxiliary alarm (relay) 2.5mm² rising clamp terminal block
Control signal 2.5mm² rising clamp terminal block
Environmental Protection: IP20
Fusing 80kVAR: 160EET (160A) High-Speed Semiconductor type fuse, or equivalent
Fusing 100kVAR: 200EET (200A) High-Speed Semiconductor type fuse, or equivalent
Working temperature: +65°C (maximum operational)
Dimensions: 270 x 250 x 130mm
Fixing centres: 4 x 4.5mm-clear keyhole slots on fixing centres 227 x 200mm
Weight: 5.6kg

RS Product Codes
919-6232 PFC2 80kVAR
919-6236 PFC2 100kVAR

Warning

  • Metal parts, in particular the case may get very hot when the unit is fully operational.
Specifications
Attribute Value
Current Rating 150A
Weight 5.6kg
Mounting Type Panel Mount
Dimensions 270 x 250 x 130mm
Fixing Centres 227 x 200mm
Length 270mm
Width 250mm
Height 130mm
Maximum Operating Temperature +65 °C
On back order for despatch 27/03/2020, delivery within 5 working days from despatch date.
Price (ex. GST) Each
$ 1,348.04
(exc. GST)
$ 1,550.25
(inc. GST)
units
Per unit
1 - 4
$1,348.04
5 - 9
$1,251.76
10 +
$1,231.54
Related Products
UHF (SO 239) & N-type (female) single pole, ...
Description:
UHF (SO 239) & N-type (female) single pole, two way coaxial switches for radio frequency applications. Break-before-make switch action. Minimal insertion loss and low VSWRWide frequency range and power handling capacity. High reliability gold plated terminal centre connections. Zinc alloy ...
UHF (SO 239) & N-type (female) single pole, ...
Description:
UHF (SO 239) & N-type (female) single pole, two way coaxial switches for radio frequency applications. Break-before-make switch action. Minimal insertion loss and low VSWRWide frequency range and power handling capacity. High reliability gold plated terminal centre connections. Zinc alloy ...
Compact, solid state, dual voltage device for manual ...
Description:
Compact, solid state, dual voltage device for manual proportional control of resistive loads using variable bursts of energy coincidental with mains zero crossover, ensuring complete sine wave cycles are passed through to the load. High surge 26A triac. Load rating; ...
The PRx-E thyristor stack units provide full seamless ...
Description:
The PRx-E thyristor stack units provide full seamless control of 1/3-phase resistive loads. Burst-firing control stack uses fast pulse zero-voltage switching technology to minimise flicker and RFI problems. Integral fusing, temperature trip, automatic reset and heatsink. Housed in bespoke enclosures ...