Omron OFF Delay Single Timer Relay, 1 → 12 s, 10 → 120 s, SPDT, 200 → 240 V ac

  • RS Stock No. 733-4943
  • Mfr. Part No. H3DKHDLAC200240V
  • Manufacturer Omron
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
Product Details

True Off Delay - H3DK-H Series

Set two time ranges with each timer from 0.1 → 12 seconds (S Series) and from 1 → 120 seconds (L Series)
Operating mode: Power OFF Delay
DIN rail track mounting
Operating/resetting method: Instantaneous operation/time-limit reset
6 terminals
Insulation resistance: 100 MΩ min. at 500 Vdc
Protection class rating: IP30 (Terminal block: IP20)

Approvals

CE, cURus, CCC, LR

True Off Delay

Specifications
Attribute Value
Supply Voltage 200 → 240 V ac
Time Range 1 → 12 s, 10 → 120 s
Mode of Operation OFF Delay
Mounting Type DIN Rail
Number of Timer Functions Single
Series H3DK
Time Increment Seconds
Current Maximum 5 A
Maximum Voltage 30 V dc, 250 V ac
Minimum Operating Temperature -20°C
Maximum Operating Temperature +55°C
Switch Configuration SPDT
Width 22.5mm
Length 89.4mm
Depth 100mm
4 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 141.69
(exc. GST)
$ 162.94
(inc. GST)
units
Per unit
1 - 2
$141.69
3 - 4
$129.30
5 +
$120.25
Related Products
Interval (Single Shot), Multi-voltage timer LEIN in a ...
Description:
Interval (Single Shot), Multi-voltage timer LEIN in a 17.5mm DIN rail housing. Supply initiated Interval (Single Shot) timing function7 selectable time ranges. Fine adjustment of selected time range. Multi-voltage input1x SPDT relay output Green LED indication for supply and timing ...
Solid-sate time delay relays with push in plus ...
Description:
Solid-sate time delay relays with push in plus technology are used for in-panel applications. They are ideal in space saving applications due to their slim design and help reduce work in control panels. The timers reduce power consumption by up ...
Off-delay of 0.5 s to 60 min configurable ...
Description:
Off-delay of 0.5 s to 60 min configurable (depending on type)With auxiliary voltage (nominal voltage)110 AC → 240 V or 24 Vac / Vdc (depending on type)Control input B1 can be controlled with nominal voltage; no volt-free control contact requiredLED ...
7 time ranges. Wide range input. Change the ...
Description:
7 time ranges. Wide range input. Change the time range during operation. Change the functional operation in de-energised state. High repeat accuracy. Integrated overvoltage protectionLED status display. Slim design.