MTL 2 Channel Isolation Barrier With NAMUR Input, Relay Output, 10.5 V max, 14mA max

  • RS Stock No. 703-7040
  • Mfr. Part No. MTL5516C
  • Manufacturer MTL
Technical data sheets
Legislation and Compliance
RoHS Status: Exempt
COO (Country of Origin): GB
Product Details

5500 Series IS Interface Units

The MTL5500 series is the latest generation of MTL isolators. Incorporating advanced circuit design and innovative isolating transformer construction. The compact 16mm wide design reduces weight and gives a high packing density and reduction in power consumption. They build on the success of the MTL5000 series to bring the benefits of galvanic isolation with exceptional design and reliability.,II (I) GD (Ex ia) IIC,IECEx, ATEX (Baseefa) FM, CSA

3-Port Isolation
High Packing density
Low power dissipation
Multi-channel I/O modules
Compatible with preceding MTL5000 series
Assessed for Functional safety IEC61508 applications
Required EX numbers and information displayed on cover where applicable

Specifications
Attribute Value
Barrier Type Galvanic
Number of Channels 2
Supply Voltage 20 → 35 V dc
Safety Voltage Maximum 10.5 V
Safety Current Maximum 14mA
Signal Type NAMUR Input, Relay Output
Minimum Operating Temperature -20°C
Maximum Operating Temperature +60°C
Hazardous Area Certification ATEX
30 : Next working day
62 Within 7 working day(s) (Global stock)
Price (ex. GST) Each
Was $533.41
$ 399.61
(exc. GST)
$ 459.55
(inc. GST)
units
Per unit
1 +
$399.61
Related Products
Straightforward DIN-rail mounting. Low cost per channel. High ...
Description:
Straightforward DIN-rail mounting. Low cost per channel. High packing densities. Simplified installation and maintenance using plug-in connectors. Dimensions: 110 x 104 x 16.2mm.
Terminal blocks to go with the PI-EX Series. ...
Description:
Terminal blocks to go with the PI-EX Series. Ex PI-EX-TB - Ex base terminal block for intrinsically safe signals with knife disconnection and test connections. Ex PI-EX-TB/T - Ex-basic terminal block, with knife disconnection and integrated temperature measurement of the ...
Using a dual channel barrier impedes a direct ...
Description:
Using a dual channel barrier impedes a direct grounding of the intrinsically safe circuit. The ground is only made in the event of a failure, if the zener diodes conduct. This circuit also suppresses influences of external circuits. Typical application ...
6185 type is a 1-, 2- or 4-channel ...
Description:
6185 type is a 1-, 2- or 4-channel galvanic isolation module. Inputs and outputs are floating and galvanically separated. Elimination of ground loops and measurement of floating signals. Especially useful in applications necessitating an unproblematic transmission of current signals according ...