2 Channel HART Isolating Transducer, 250 V max

  • RS Stock No. 808-6538
  • Mfr. Part No. IM33-22EX-HI-24VDC
  • Manufacturer Turck
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

Isolating Transducer

Professional range of galvanically isolated Isolating transducers for the transmission of a unattenuated output signal to the non-Ex area. This series is environmentally versatile and comes with a variety of approvals, meaning the IM signal conditioning series can be installed in a comprehensive range of applications

Features of the IM Isolating Transducer Series
Suitable for Zone 2 installation
Safety Integrity Level (SIL) 2
Removable screw-termination terminal blocks, with 2mm test box
Complete galvanic isolation
4 - 20mA input & output circuits
Supports HART communication and 2-wire active & passive 3-wire transmitters
Connection for HART handheld unit supported

Standards

ATEX, IECEx, FM, UL, GOST

//media.rs-online.com/t_line/R8086538-01.jpg

Turck Banner DIN Rail Mounting

Specifications
Attribute Value
Barrier Type Galvanic
Number of Channels 2
Supply Voltage 24 V dc
Safety Voltage Maximum 250 V
Minimum Operating Temperature -25°C
Maximum Operating Temperature +70°C
Operating Temperature Range -25 → +70 °C
13 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 708.17
(exc. GST)
$ 814.40
(inc. GST)
units
Per unit
1 +
$708.17
Related Products
The solution for applications with 3-wire transmitters is ...
Description:
The solution for applications with 3-wire transmitters is implementing a combination of one 28V, 300Ω and one 28V barrier with diode return. Special consideration should be given to the internal voltage drop due to the diode return.,Typical application - 4-20mA ...
Zener barriers provide cost saving Ex-protection for various ...
Description:
Zener barriers provide cost saving Ex-protection for various applications in process automation systems. The amount of energy transferred to the hazardous location is limited to a safe level incapable of igniting the explosive atmosphere. Typical application - transmitters, transducers, solenoid ...
The MTL5500 series is the latest generation of ...
Description:
The MTL5500 series is the latest generation of MTL isolators. Incorporating advanced circuit design and innovative isolating transformer construction. The compact 16mm wide design reduces weight and gives a high packing density and reduction in power consumption. They build on ...
For operating proximity sensors and switches in Ex ...
Description:
For operating proximity sensors and switches in Ex areas The signals are transmitted via transistor outputs (passive) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.