Circuit Trips | Auto Reclosers | RS
Recently searched

    Circuit Trips

    Circuit trips react to ground faults, short circuits or thermal overload in circuit breakers. A circuit trip opens the circuit in the event of a faulty condition. The trip becomes activated when it senses heat from an overload or high current from a short circuit.

    What are the different types of circuit trips?

    There are two types of circuit trips: electromechanical and electronic. An electromechanical circuit trip has two moving parts that work together to determine when to open the circuit. The two parts are a current-sensitive device and a thermal-sensitive device. An electric circuit trip is less mechanical as it's a programmable device. It measures and times the current flowing through the circuit breaker, electronically delivering a trip signal when it's needed.

    How to choose the right circuit trips

    Choosing the right circuit trips depends on the circuit or device and appliance you're using it for. There are various features that should be considered when selecting the right circuit trips, such as rated-control voltage and the current rating.

    An auto recloser is a type of circuit breaker equipped with a mechanism that automatically closes the breaker after it has been opened due to a fault. Reclosers are used to detect overcurrent and interrupt momentary faults in electrical distribution networks. To prevent damage, each station along a network is protected with circuit breakers which turn the power off if there is a short circuit. Reclosers are programmed to automate the reset process and start the restoration service.

    Why Have an Auto Recloser?

    Firstly, reclosers prevent transient short circuits from triggering prolonged power outages. This could be a broken tree branch momentarily hitting an overhead cable before it hits the ground. Having a recloser results in a better service to the customer as the power is restored within a few seconds.

    Secondly, the recloser is able to restore power automatically without the requirement of an engineer unless the fault is more serious.

    324 Products showing for Circuit Trips

    RS PRO
    5A
    -
    HS
    MS32 & MSB32 Motor Protection Circuit Breakers
    Auxiliary Release
    -
    -
    -
    ABB
    -
    SACE Tmax XT
    SOR-C XT1-XT4
    Tmax XT1, Tmax XT2, Tmax XT3, Tmax XT4
    Shunt Trip
    24 → 30V ac/dc
    -
    -
    Schneider Electric
    3A
    Acti 9
    iMX
    ARA, ic60 MCB, IDPN Vigi, ild Double Terminal, ilD MCB, iSW-NA, RCA
    Shunt Trip
    100 → 415 V ac, 110 → 130V dc
    Yes
    Green Premium
    Schneider Electric
    40A
    Compact
    Micrologic 2.2
    Compact NSX 100/160/250 Circuit Breakers
    -
    690V ac
    Yes
    Green Premium
    Schneider Electric
    -
    TeSys D
    LAD
    LR3D Series, LRD Series
    Remote Tripping Device
    220 V ac/dc, 230V ac/dc
    Yes
    Green Premium
    Siemens
    32A
    -
    Sentron
    -
    Remote Control
    24V dc
    -
    -
    Schneider Electric
    -
    -
    MX
    ComPact NS630b → 1600, ComPact NS1600b → 3200 Series, MasterPact NT, Masterpact NW
    Shunt Trip
    -
    -
    -
    ABB
    -
    S2C-UA
    S2C
    DS200, DS201, DS202C, F200, S200, SN201
    Undervoltage Release
    24V dc
    -
    -
    Schneider Electric
    20A
    Acti 9
    iPB
    -
    Push Button
    250V ac
    Yes
    Green Premium
    Schneider Electric
    20A
    Acti 9
    A9E1
    -
    -
    250V (Volts)
    Yes
    Green Premium
    Schneider Electric
    20A
    Acti 9
    iSSW
    DIN rail mounting support
    Shunt Trip
    250V ac
    -
    -
    Dold
    16A
    -
    IK 8805
    -
    Remote Switch
    -
    -
    -
    Schneider Electric
    100A
    Acti 9
    SEA9TB
    Acti 9 Isobar A Type Distribution Boards, Acti9 Isobar B Type Distribution Boards
    -
    -
    Yes
    Green Premium
    Schneider Electric
    -
    -
    MN
    ComPact NS630b → 1600, ComPact NS1600b → 3200, MasterPact NT, Masterpact NT NAVY, Masterpact NW, Masterpact NW NAVY Series
    Shunt Trip
    -
    -
    -
    Eaton
    -
    -
    -
    FAZ Series MCB/RCBO
    Shunt Trip
    12 → 110 V ac, 12 → 60V dc
    -
    -
    Schneider Electric
    250A
    ComPacT NSX100...250
    LV4
    ComPact (ComPact NSX400) Circuit Breaker
    Earth Leakage Add-on Protection Module
    220 - 440V ac
    -
    -
    Schneider Electric
    80A
    Acti 9
    iMN
    ARA, iC40, ic60 MCB, iC65, iDPN (China version), IDPN Vigi, ild Double Terminal, ilD MCB, iSW-NA, RCA double terminals MCB
    Undervoltage Release
    220 → 240V ac
    Yes
    Green Premium
    Schneider Electric
    -
    Acti 9
    iPB
    -
    -
    250V (Volts)
    Yes
    Green Premium
    Schneider Electric
    1 → 6A
    Acti 9
    iC60H
    IC60, IID, ISW-NA
    Shunt Trip
    100 V ac, 110 V dc, 130 V dc, 230 V ac, 415V ac
    -
    -
    Schneider Electric
    -
    Acti 9
    iC60
    Circuit Breaker
    Auto Recloser
    -
    Yes
    Green Premium
    Results per page