Steam Traps

Steam traps are a type of automatic valve that filters out condensed steam and non-condensed steam, such as air without letting steam escape. Steam is used for regularly for heating or as a driving force for mechanical power. Used to ensure that the steam is not wasted in such applications.Mechanical TrapsMechanical traps sense the difference in density between steam and condensate. Condensate from this type of trap is continually discharged, leaving none to the process. These are the most commonly used steam traps utilised today in systems that require large discharge capacities. Bucket traps use an inverted bucket as a float device that releases the condensate once the bucket to loses buoyancy and sinks, opening the valve allowing the condensate to be released.A floating ball trap is a simple mechanical trap that uses the weight of the ball, which acts as a lever keeping the valve closed. As condensate enters the trap it raises the float, opening the valve releasing the condensate.Thermostatic TrapsThermostatic traps utilise a temperature sensing element to determine when to discharge the condensate. Balanced pressure traps operate by balancing the steam pressure and internal pressure of the thermostatic element. At start-up the valve is open, but once the steam reaches a certain temperature bellow expand to close it. These steam traps can be used in steam tracing applications.Thermodynamic TrapsThermodynamic traps use the difference in velocity between steam and condensate to operate. As steam enters, it can be freely discharged through a valve. When steam reaches the underside of the disc its velocity is much higher than condensate, creating a pressure drop which closes the valve head. The valve stays shut until the steam pressure above the disc drops, allowing the valve to open and the discharge cycle to repeat.Steam Trap TypesThere are three main types of steam traps to consider, these are:ApplicationsSteam traps can be used anywhere there is a steam system and a need to discharge condensate. These include: Industrial dryers Laundries Space heating Steaming ovens

...
Read more Read less

Filters

Viewing 21 - 40 of 63 products
Results per page
Description Price Trap Type Connection Orientation Maximum Working Pressure Maximum Temperature Body Material Gasket Material Connection Gender Connection Size Thread Standard or Connection Type
RS Stock No. 917-1892
Mfr. Part No.440675
$1,723.28
Each
units
- - Vertical 20 bar - Stainless Steel - - - -
RS Stock No. 917-1895
Mfr. Part No.551274
$828.94
Each
units
Thermostatic - Horizontal, Vertical 10 bar - SG Iron Stainless Steel Female - -
RS Stock No. 917-1732
Mfr. Part No.348539
$1,130.38
Each
units
- - Vertical - - Carbon Steel - - - -
RS Stock No. 507-5857
Mfr. Part No.1458500
$673.73
Each
units
Ball Float 3/4 in BSP Horizontal 14.6 bar +250°C Stainless Steel Graphite - 3/4in BSP
RS Stock No. 917-1760
Mfr. Part No.481117
$1,075.07
Each
units
Thermostatic - Vertical 6 bar +165°C Stainless Steel - - 3/4in -
RS Stock No. 799-8894
Mfr. Part No.29005
$301.53
Each
units
Float & Thermostatic 3/4 in Horizontal, Vertical 14 bar +198°C SG Iron Graphite, Stainless Steel - 3/4in BSP
RS Stock No. 917-1915
Mfr. Part No.551279
$1,288.21
Each
units
Thermodynamic - Horizontal, Vertical 40 bar - - Stainless Steel Female - -
RS Stock No. 917-1754
Mfr. Part No.445682
$1,043.73
Each
units
Thermostatic - Vertical 6 bar +165°C Stainless Steel - - 1/2in -
RS Stock No. 917-1937
Mfr. Part No.551285
$1,482.43
Each
units
Thermostatic - Horizontal, Vertical 14 bar - SG Iron Stainless Steel Female - -
RS Stock No. 917-1899
Mfr. Part No.551275
$964.69
Each
units
Thermostatic - Horizontal, Vertical 10 bar - SG Iron Stainless Steel Female - -
RS Stock No. 917-1738
Mfr. Part No.348538
$1,089.86
Each
units
- - Vertical - - Carbon Steel - - - -
RS Stock No. 917-1924
Mfr. Part No.551283
$964.69
Each
units
Thermostatic - Horizontal, Vertical 14 bar - SG Iron Stainless Steel Female - -
RS Stock No. 799-8884
Mfr. Part No.29002
$310.40
Each
units
Float & Thermostatic 1/2 in Horizontal, Vertical 10 bar +198°C SG Iron Graphite, Stainless Steel - 1/2in BSP
RS Stock No. 917-1906
Mfr. Part No.551278
$928.53
Each
units
Thermodynamic - Horizontal, Vertical 40 bar - - Stainless Steel Female - -
RS Stock No. 917-1710
Mfr. Part No.348536
$655.03
Each
units
- - Vertical - - Carbon Steel - - - -
RS Stock No. 917-1928
Mfr. Part No.551284
$1,482.43
Each
units
Thermostatic - Horizontal, Vertical 4.5 bar - SG Iron Stainless Steel Female - -
RS Stock No. 917-1713
Mfr. Part No.348535
$620.57
Each
units
- - Vertical - - Carbon Steel - - - -
RS Stock No. 365-6325
Mfr. Part No.1534197
$779.05
Each
units
Thermodynamic 3/4 in NPT Female Horizontal 42 bar +400°C Stainless Steel Graphite Female 3/4in NPT
RS Stock No. 720-9245
$377.14
Each
units
Inverted Bucket 1/2 in BSP Female Horizontal 8 bar +230°C Iron - Female 1/2in BSP
RS Stock No. 917-1726
Mfr. Part No.348537
$612.88
Each
units
- - Vertical - - Carbon Steel - - - -
Related Products
TD42L designed for relatively small condensate loads and ...
Description:
TD42L designed for relatively small condensate loads and ideal for mains drainage applications. TD42H is ideal for process type loads. Screwed BSP with in-built strainer. Compact and lightweight, reducing installation costs. Positive discharge with clean tight shut-off. No back-up of ...
All units PN16 with Stainless Steel internal parts ...
Description:
All units PN16 with Stainless Steel internal parts and Reinforced Exfoliated Graphite gaskets, Straight Orientation; Maximum Operating Pressure - 14bar g; Maximum Allowable Pressure - 16 bar g; Maximum Cold Hydraulic Test Pressure - 24bar g; Cover Bolts Material - ...
The FT range of ball float steam traps ...
Description:
The FT range of ball float steam traps from Spirax Sarco are the most popular mechanical steam traps in the world. The new FTGS14 has been designed to offer perfect condensate drainage and air venting for process, heating and mains ...
Body design conditions PN40Compact design reduces installation space ...
Description:
Body design conditions PN40Compact design reduces installation space compared to other steam traps. High resistance to superheat and water hammer ensuring long working life and low maintenance. Automatically discharges air and incondensable gases to aid rapid plant warm up. Steel ...