- RS Stock No.:
- 813-446
- Brand:
- RS PRO
67 In stock for delivery within 7 working day(s)
Added
Price (ex. GST) Each
Was $66.45
You pay
$56.48
(exc. GST)
$64.95
(inc. GST)
Units | Per unit |
1 - 49 | $56.48 |
50 - 99 | $54.91 |
100 - 249 | $52.66 |
250 - 1249 | $51.20 |
1250 + | $42.14 |
- RS Stock No.:
- 813-446
- Brand:
- RS PRO
Technical data sheets
Legislation and Compliance
- COO (Country of Origin):
- GB
Product Details
Chassis Mount
RS PRO presents this 3-way chassis mount chassis package as part of its electronic components range. Two flexible wire ended single and three phase contact arc suppressors designed specifically to reduce contact arc when switching reactive loads.
These RC suppressors are suitable for industrial applications employing high power control circuitry. May be connected across a switch to improve contact life or in a parallel delta configuration to protect thyristors and solid state relays.
These RC suppressors are suitable for industrial applications employing high power control circuitry. May be connected across a switch to improve contact life or in a parallel delta configuration to protect thyristors and solid state relays.
Features and Benefits:
Two flexible wire ended single and three phase contact arc suppressors designed specifically to reduce contact arc when switching reactive loads
These RC suppressors are suitable for industrial applications employing high power control circuitry. May be connected across a switch to improve contact life or in a parallel delta configuration to protect thyristors and solid state relays. Will also improve dV/dt
These RC suppressors are suitable for industrial applications employing high power control circuitry. May be connected across a switch to improve contact life or in a parallel delta configuration to protect thyristors and solid state relays. Will also improve dV/dt
How do capacitors store energy?
Capacitors store energy when they are connected to a voltage source in a circuit, for example when connected to a battery or electrical source. The capacitor will charge up to the same voltage as the voltage it is connected to, it does this when a current flows.
How do capacitors work?
Capacitors contain two metal plates, and a dielectric material in between those two plates. An electric field is formed when voltage is applied over the plates. One plate collects negative charge the other positive. The effect of a capacitor is called capacitance.
Warning
These devices are designed for connecting directly across a mains supply but should NOT be used in positions where failure of the capacitor would expose anyone to electric shock.
Approvals
7777
Specifications
Attribute | Value |
---|---|
Series | DLFP |
Capacitance | 330nF |
Voltage | 500V ac |
Resistance | 33Ω |
Package/Case | Chassis |
Mounting Type | Chassis Mount |
Number of Elements | 3 |
Capacitance Tolerance | ±20% |
Resistance Tolerance | ±30% |
Dimensions | 65 x 61 x 31mm |
Height | 61mm |
Depth | 31mm |
Length | 65mm |
Minimum Operating Temperature | -40°C |
Operating Temperature Range | -40 → +70 °C |
Maximum Operating Temperature | +70°C |