SICK MOC3ZA Series Safety Controller, 24 V dc
- RS Stock No.:
- 285-8879
- Mfr. Part No.:
- MOC3ZA-KAZ33D3
- Brand:
- SICK
Subtotal (1 unit)*
$1,694.66
(exc. GST)
$1,948.86
(inc. GST)
FREE delivery for orders over $60.00 ex GST
In Stock
- Plus 2 unit(s) shipping from 08 December 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | $1,694.66 |
*price indicative
- RS Stock No.:
- 285-8879
- Mfr. Part No.:
- MOC3ZA-KAZ33D3
- Brand:
- SICK
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | SICK | |
| Series | MOC3ZA | |
| Safety Category | 4 | |
| SIL | SIL 3 | |
| Supply Voltage | 24 V dc | |
| Terminal Type | Screw Terminal | |
| IP Rating | IP20, IP40 | |
| Dimensions | 45 x 112 x 121 mm | |
| Width | 45mm | |
| Length | 112mm | |
| Depth | 121mm | |
| Select all | ||
|---|---|---|
Brand SICK | ||
Series MOC3ZA | ||
Safety Category 4 | ||
SIL SIL 3 | ||
Supply Voltage 24 V dc | ||
Terminal Type Screw Terminal | ||
IP Rating IP20, IP40 | ||
Dimensions 45 x 112 x 121 mm | ||
Width 45mm | ||
Length 112mm | ||
Depth 121mm | ||
- COO (Country of Origin):
- DE
Overview
The Standstill Monitor MOC3ZA is a safety device for machine drives and serves to protect against dangerous movements. It also measures the residual voltage meaning that no additional sensors are required for the purpose of standstill monitoring. This ren
The positively guided safety contacts enable the device to be connected to all of SICK's safe control solutions.
At a glance
Standstill monitoring by means of residual voltage measurement
3 normally open and 1 normally closed positively guided safety contacts
2 application diagnostic outputs for semiconductors
1 application diagnostic output normally open
PL e (EN ISO 13849), S
3 normally open and 1 normally closed positively guided safety contacts
2 application diagnostic outputs for semiconductors
1 application diagnostic output normally open
PL e (EN ISO 13849), S
Your Benefit
Quick mounting and installation thanks to the lack of additional wiring requirements
Simple commissioning with a screwdriver
Easy to retrofit as the subsequent mounting of sensors is not necessary
Simple commissioning with a screwdriver
Easy to retrofit as the subsequent mounting of sensors is not necessary
Applications
Note
Related links
- SICK MOC3ZA Series Safety Controller 24 V
- SICK MOC3ZA Series Safety Controller 230 V
- SICK FX3 Series Safety Controller, 24 V dc
- SICK UE410 Series Safety Controller, 24 V dc
- SICK Flexi Soft FX3 Series Safety Controller 48 Safety Outputs, 24 V dc
- Schneider Electric Preventa Safety automation Preventa Series Safety Controller, 24 V dc
- Bernstein AG SCx Series Safety Controller, 24 V dc
- ABB Tina Series Safety Controller, 24 V dc