UE410 Input/Output Module, 5 Inputs, 3 Outputs, 24 V dc

  • RS Stock No. 701-9180
  • Mfr. Part No. UE410-XM3
  • Manufacturer Sick
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

UE410-MM3 Muting Main Unit and UE410-XM3 Muting Extension

Functions include muting and override, concurrence monitoring, monitoring total muting time, sensor gap monitoring, end of muting by ESPE. Applications: Opto-electronic protective devices and non-contact safety switches

2 or 4 muting sensors
1 reset/restart input and external device monitoring
Activation and time adjustable 0.33 to 60 min
Type of output safety capable outputs: PNP semiconductors, short-circuit protected, cross-circuit monitored
Maximum output current: 2A
Maximum response time: 13 ms
Maximum switch on time: 10 s
Maximum power consumption: 3 W
Category 4 (EN ISO 13849), SIL3 (IEC 61508), SILCL3 (IEC 62061), PL e (EN ISO 13849)

Specifications
Attribute Value
Series UE410
Type Input/Output Module
For Use With UE410
Supply Voltage 24 V dc
Number of Inputs 5
Number of Outputs 3
Mounting Style DIN Rail
Terminal Type Plug In
Dimensions 96.5 x 22.5 x 120.8 mm
On back order for despatch 16/10/2019, delivery within 5 working days from despatch date.
Price (ex. GST) Each
$ 656.37
(exc. GST)
$ 754.83
(inc. GST)
units
Per unit
1 +
$656.37
Related Products
Extension modules for PNOZ sigma series safety blocks.The ...
Description:
Extension modules for PNOZ sigma series safety blocks.The extension blocks provide reinforcement and increase the number of safety contacts on a base device.The contact extension block expands an existing electrical circuit. Safety is still guaranteed, even if a component fails.Removable ...
Professional range of IDEM VIPER Safety Relays with ...
Description:
Professional range of IDEM VIPER Safety Relays with pluggable and screw terminals. The safety relays incorporate expansion units. The relays can be directly wired to increase the number of safety output contacts. Designed to meet the latest safety standard and ...
Input expander / PFB. For SD-Interface devicesPassive field ...
Description:
Input expander / PFB. For SD-Interface devicesPassive field box for series-wiringFor devices with M12 Connector, 8-poleFor up to 4 safety switchgearsFuse protected device portsHeavy duty version for field installationProtection class IP67.
8 safety inputs8 control outputs (with 2 test ...
Description:
8 safety inputs8 control outputs (with 2 test pulse generators)Safety functions: E-stop function; machine control (e.g.PSDI); differentiation between man and material (muting); control modes and operating mode selectionConnects to main system via cable glandCategory 4 (EN ISO 13849), SIL3 (IEC ...