Sick Muting Sensor, For Use With M4000 Series

  • RS Stock No. 271-518
  • Mfr. Part No. UE403-A0930
  • Manufacturer Sick
Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): DE
Product Details

UE403, Safety Switch Amplifier for Muting

The advantages of using the UE403 in conjunction with the M4000 series of light curtains are: local processing of signals (fewer cables, lower installation outlay, more control cabinet space); supply voltage for muting sensors direct from UE403; local IP65 connection makes additional control cabinet unneccessary; no reconfiguration is required when photoelectric switches are replaced.

Connection of 2-4 muting sensors, external muting lamp, reset and override control switch, conveyor belt stop signal
Concurrence monitoring
Monitoring of total muting time
Sensor gap monitoring and test
Partial blanking
End of muting by ESPE
Integrated override

Note

For use with the M4000 series of light curtains
UE403 to M4000. Connection cable sold separately

Standards

IEC 61508, EN61496-1&2

Perimeter and Access Guard

3 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 626.08
(exc. GST)
$ 719.99
(inc. GST)
units
Per unit
1 +
$626.08
Related Products
Professional range of Schneider single-beam photo electric sensors. ...
Description:
Professional range of Schneider single-beam photo electric sensors. The sensors incorporate 2 standard safety contacts and 4 solid stat outputs. Screw terminals. 2 N/O safety outputsIP40 enclosuresIP20 terminalsScrew terminals.
Professional range of Schneider Electric safety monitoring relays ...
Description:
Professional range of Schneider Electric safety monitoring relays from the Preventa range. The relays incorporate a manual reset and screw terminals. Designed for dynamic monitoring of double bodies solenoid valves. All models are highly reliable and excellent quality. Manual resetScrew ...
The ABB Jokab SSR10M is a safety relay ...
Description:
The ABB Jokab SSR10M is a safety relay with 3NO+1NC contacts and with 85VAC to 265VAC (50/60 Hz)/120-375VDC power supply. This is used with two channels with equivalent contacts devices. • Compact in dimension 120mmx22.5mmx120mm• Expansion of safety controller outputs ...
Adjustable off delayNo auxiliary voltageOutput: 1 NC, 1 ...
Description:
Adjustable off delayNo auxiliary voltageOutput: 1 NC, 1 force guided NOLED to display switch positionDelayed switch-off in safety-oriented circuits(EU Directive for machines 89/392/EEC, IEC 255, DIN VDE 0435).