Wieland 230 V ac Safety Relay Dual Channel With 3 Safety Contacts and 1 Auxilary Contact

  • RS Stock No. 122-2495
  • Mfr. Part No. R1.188.1460.0
  • Manufacturer Wieland
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

SNA 4063K Safety Relay for all Devices including Elevators and Heaters

Stop-Category 0 acc. EN 60204-1
Applications up to Category 4 acc. EN 954-1, to SIL 3 according to EN62061 and PL e according to EN13849-1
Can be used as emergency stop and safety gate monitor
Manual reset with self-monitoring on each ON-OFF cycle
Cross monitoring
One or two-channel wiring
External device monitoring (EDM)
LED indication

Approvals

TUV, cULus

Specifications
Attribute Value
Supply Voltage 230 V ac
Number of Channels 2
Auxiliary Contacts 1
Function Elevator System, Emergency Stop, Light Beam/Curtain, Safety Switch/Interlock
Safety Contacts 3
Range SafeRELAY
Reset Method Manual, Monitored
Terminal Type Screw
Standards Met CCC, CPT, CULus, EN 50156-1, EN 61511, EN 62061, EN 81-1, EN ISO 13849-1, FS, GL, GOST R, TUV
Depth 96.5mm
Width 114mm
Length 22.5mm
3 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 299.46
(exc. GST)
$ 344.38
(inc. GST)
units
Per unit
1 +
$299.46
Related Products
The IDEMAG CPR safety switch has been developed ...
Description:
The IDEMAG CPR safety switch has been developed for non-contact interlocking of hinged, sliding or removable guard doors.It is ideal for applications that require a wide tolerance to misalignment, high switching capacity or high level of hygiene.When used with a ...
This is the main module in the UE410 ...
Description:
This is the main module in the UE410 FLEXI system. 8 available programs can be set using rotary switches (e.g. emergency stop pushbuttons, Type IIIA and IIIC two-hand controls, safety interlock switches, non-contact switches, testable Type 2 sensors, hold to ...
Functions include muting and override, concurrence monitoring, monitoring ...
Description:
Functions include muting and override, concurrence monitoring, monitoring total muting time, sensor gap monitoring, end of muting by ESPE. Applications: Opto-electronic protective devices and non-contact safety switches. 2 or 4 muting sensors1 reset/restart input and external device monitoringActivation and time ...
Professional range of Schneider Electric safety contactor with ...
Description:
Professional range of Schneider Electric safety contactor with pre-defined functions from the Preventa range. The controllers incorporate 2 independent functions. All models are highly reliable and excellent quality. 2 independent functionsDin RailIP20 rated terminalsIP40 rated enclosure.