Carroll & Meynell, 1.65kVA CM3300WM0 Safety Transformer, 230V ac, 15A

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): GB
Product Details

Single Phase, 230Vac Input, 110Vac Output Transformers

High quality wall mounting safety isolating transformers designed to ensure safe electrical distribution for power tools etc in industrial, garage and other fixed installations.

Double wound
110V secondaries centre tapped to earth to minimise shock risk
Sheet steel IP22 type wall mounting enclosure
Re settable thermal cut out trip in primary circuit to prevent overload
Thermal safety overload fuse embedded into primary winding
20mm conduit entry on both sides of case

Note

Tool rating is defined in BSEN 61558-2-23 as 5 minutes on and 15 minutes off. Maximum output must not exceed 16A per socket outlet.

Approvals

8888

Standards

BSEN 61558-2-23

Specifications
Attribute Value
Primary Voltage Rating 230V ac
Secondary Voltage Rating ±110V ac
Power Rating 1.65kVA
Output Current 15A
Series CM3300WM0
Plug Type Hard Wire L-N-E
Weight 18kg
Length 240mm
Width 200mm
Depth 255mm
Dimensions 240 x 200 x 255mm
Mounting Type Wall Mount
Maximum Operating Frequency 60Hz
Minimum Operating Frequency 50Hz
48 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
Was $700.80
$ 528.43
(exc. GST)
$ 607.69
(inc. GST)
units
Per unit
1 +
$528.43
Related Products
Autowound transformers for step-up or step-down of mains ...
Description:
Autowound transformers for step-up or step-down of mains voltages at 50/60Hz. Compact construction. Full varnish impregnation. Fully shrouded. Four-hole fixing for permanent installation. Terminal blocks with protective covers (except 50VA which has leads)100% electrical and flash tested (2kV winding to ...
Autowound transformers for step-up or step-down of mains ...
Description:
Autowound transformers for step-up or step-down of mains voltages at 50/60Hz. Compact construction. Full varnish impregnation. Fully shrouded. Four-hole fixing for permanent installation. Terminal blocks with protective covers (except 50VA which has leads)100% electrical and flash tested (2kV winding to ...
The Honeywell 2-way 230VAC motorised zone valve has ...
Description:
The Honeywell 2-way 230VAC motorised zone valve has a pipe of 1in. The maximum operating pressure of this valve is 8.6bar and power consumed is 6W. It is designed to control the flow of water in iron and copper pipe ...
Applications include fridges, freezers, air conditioning and coolers. ...
Description:
Applications include fridges, freezers, air conditioning and coolers. Designed to accurately stabilise large variations of mains voltage. Includes lightning surge/spike protection. Disconnects output when mains voltage is too high or too low3 minute wait period to allow compressor gases to ...