RS PRO Signal Conditioner, Voltage Input, Current Output, 24 → 230V ac Supply
- RS Stock No.:
- 629-522
- Brand:
- RS PRO
Bulk discount available
Subtotal (1 unit)*
$591.00
(exc. GST)
$679.65
(inc. GST)
FREE delivery for orders over $60.00 ex GST
In Stock
- 10 unit(s) ready to ship from another location
- Plus 4 unit(s) shipping from 09 February 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 - 4 | $591.00 |
| 5 + | $486.39 |
*price indicative
- RS Stock No.:
- 629-522
- Brand:
- RS PRO
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | RS PRO | |
| Module Type | Signal Isolator | |
| Input Signal Type | Voltage | |
| Output Signal Type | Current | |
| Input Range | 0 → 10V dc | |
| Output Range | 4 → 20mA | |
| Supply Voltage | 24 → 230V ac | |
| Mounting Type | DIN Rail Mount | |
| Operating Temperature Range | -20 → +60°C | |
| Series | TYA-202 | |
| Maximum Operating Temperature | +60°C | |
| Termination | Screw | |
| Minimum Operating Temperature | -20°C | |
| Select all | ||
|---|---|---|
Brand RS PRO | ||
Module Type Signal Isolator | ||
Input Signal Type Voltage | ||
Output Signal Type Current | ||
Input Range 0 → 10V dc | ||
Output Range 4 → 20mA | ||
Supply Voltage 24 → 230V ac | ||
Mounting Type DIN Rail Mount | ||
Operating Temperature Range -20 → +60°C | ||
Series TYA-202 | ||
Maximum Operating Temperature +60°C | ||
Termination Screw | ||
Minimum Operating Temperature -20°C | ||
RoHS Status: Exempt
- COO (Country of Origin):
- GB
Signal Conditioning Units
RS Pro single or dual trip amplifiers with the facility to arrange each trip so that the alarm condition can be above (high trip) or below (low trip) the set point. The relay can be either energise/de-energise in the alarm condition (fail-safe) or de-energise/energise in the alarm condition (non-fail safe).
Dual supply voltage operation
Bi-colour LED status indication
Front panel adjustment of "Trip Levels"
Bi-colour LED status indication
Front panel adjustment of "Trip Levels"
Input and output stages powered from separate secondaries of the supply transformer to provide 3-port isolation
Dual supply voltage operation
LED indication of "power on"
Dual supply voltage operation
LED indication of "power on"
Note
Trip settings are set via links on a PBC within the unit,Signal isolators/Converters; Four units which provide signal isolation via an opto-isolated hybrid circuit. The 0-10Vdc; 4-20mA;and 4-20mA; 0-10Vdc units also convert process signals into a required standard transmission voltage or current signals
Related links
- RS PRO Signal Conditioner Current Output, 24V ac/dc Supply
- RS PRO Signal Conditioner Voltage Input Voltage Output, 24 → 240V ac/dc Supply
- RS PRO Signal Conditioner Current 24V ac/dc Supply
- RS PRO Signal Conditioner Voltage Input Voltage Output, 16.8 → 30V Supply
- Eaton MTL Series Signal Conditioner Relay Output 230V ac Supply
- Weidmuller ACT20P Series Signal Conditioner Voltage Input 230V ac Supply, ATEX
- RS PRO Signal Conditioner Voltage Output, 230V ac Supply
- WAGO 857 Series Signal Conditioner Current Output, 24V dc Supply