RS PRO Signal Conditioner, Frequency Input, Current, Voltage Output, 16.8 → 30 V dc, 19.2 → 28.8V ac
- RS Stock No.:
- 794-8524
- Brand:
- RS PRO
Subtotal (1 unit)*
$809.72
(exc. GST)
$931.18
(inc. GST)
FREE delivery for orders over $60.00 ex GST
In Stock
- 28 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | $809.72 |
*price indicative
- RS Stock No.:
- 794-8524
- Brand:
- RS PRO
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | RS PRO | |
| Module Type | Frequency Converter | |
| Input Signal Type | Frequency | |
| Output Signal Type | Current, Voltage | |
| Input Range | 0 → 1 kHz, 0 → 10 kHz, 0 → 100 Hz, 0 → 12 kHz, 0 → 16 kHz, 0 → 2 kHz, 0 → 2.5 kHz, 0 → 20 kHz, 0 → 200 Hz, 0 → 24 kHz, 0 → 250 Hz, 0 → 28.8 kHz, 0 → 3 kHz, 0 → 4 kHz, 0 → 400 Hz, 0 → 5 kHz, 0 → 500 Hz, 0 → 6 kHz, 0 → 750 Hz, 0 → 8kHz | |
| Output Range | 0 → 10 V, 0 → 20 mA, 4 → 20mA | |
| Supply Voltage | 16.8 → 30 V dc, 19.2 → 28.8V ac | |
| Mounting Type | DIN Rail Mount | |
| Operating Temperature Range | -25 → +60°C | |
| Series | MINI MCR-2-V8-MOD-TCP | |
| Standards Met | cULus | |
| Maximum Operating Temperature | +60°C | |
| Termination | Screw | |
| Minimum Operating Temperature | -25°C | |
| Select all | ||
|---|---|---|
Brand RS PRO | ||
Module Type Frequency Converter | ||
Input Signal Type Frequency | ||
Output Signal Type Current, Voltage | ||
Input Range 0 → 1 kHz, 0 → 10 kHz, 0 → 100 Hz, 0 → 12 kHz, 0 → 16 kHz, 0 → 2 kHz, 0 → 2.5 kHz, 0 → 20 kHz, 0 → 200 Hz, 0 → 24 kHz, 0 → 250 Hz, 0 → 28.8 kHz, 0 → 3 kHz, 0 → 4 kHz, 0 → 400 Hz, 0 → 5 kHz, 0 → 500 Hz, 0 → 6 kHz, 0 → 750 Hz, 0 → 8kHz | ||
Output Range 0 → 10 V, 0 → 20 mA, 4 → 20mA | ||
Supply Voltage 16.8 → 30 V dc, 19.2 → 28.8V ac | ||
Mounting Type DIN Rail Mount | ||
Operating Temperature Range -25 → +60°C | ||
Series MINI MCR-2-V8-MOD-TCP | ||
Standards Met cULus | ||
Maximum Operating Temperature +60°C | ||
Termination Screw | ||
Minimum Operating Temperature -25°C | ||
- COO (Country of Origin):
- DE
RS PRO Analogue Output, Signal Conditioner
This analogue-output signal conditioner lets you convert frequency signals ranging from 0 to 8 kHz into one of three commonly used analogue signals – 0 V to 10V, 0 mA to 20mA or 4 mA to 20mA.
This converter can accept inputs from rotational speed sensors, rotary pulse encoders and proximity switches. Two-way isolation ensures high resolution, stability and accuracy by eliminating noise, crosstalk or unwanted ground loop currents. Part of the trusted RS PRO range, the signal conditioner is stringently tested for quality. It can handle operating temperatures of -25°C to +60°C and is designed to be easy to use in the field as its compact package easily mounts onto a DIN rail.
Commonly found in industrial control and monitoring applications, these converters are used for process monitoring, engine performance rating and data acquisition.
This converter can accept inputs from rotational speed sensors, rotary pulse encoders and proximity switches. Two-way isolation ensures high resolution, stability and accuracy by eliminating noise, crosstalk or unwanted ground loop currents. Part of the trusted RS PRO range, the signal conditioner is stringently tested for quality. It can handle operating temperatures of -25°C to +60°C and is designed to be easy to use in the field as its compact package easily mounts onto a DIN rail.
Commonly found in industrial control and monitoring applications, these converters are used for process monitoring, engine performance rating and data acquisition.
Features and Benefits
• Micro-compact frequency-to-analogue converter signal conditioner
• Choose from three output ranges of 0 to 10 V, 0 to 20 mA, 4 to 20 mA
• 20 input ranges of 0 to 1 kHz, 0 to 10 kHz, 0 to 100 Hz, 0 to 12 kHz, 0 to 16 kHz, 0 to 2 kHz, 0 to 2.5 kHz, 0 to 20 kHz, 0 to 200 Hz, 0 to 24 kHz, 0 to 250 Hz, 0 to 28.8 kHz, 0 to 3 kHz, 0 to 4 kHz, 0 to 400 Hz, 0 to 5 kHz, 0 to 500 Hz, 0 to 6 kHz, 0 to 750 Hz, 0 to 8 kHz
• Minimum operating temperature of -25°C
• Maximum operating temperature of +60°C
• DIN rail mountable
• Screw-type termination for easy use
• Complies with cULus standards for use in hazardous locations
• Choose from three output ranges of 0 to 10 V, 0 to 20 mA, 4 to 20 mA
• 20 input ranges of 0 to 1 kHz, 0 to 10 kHz, 0 to 100 Hz, 0 to 12 kHz, 0 to 16 kHz, 0 to 2 kHz, 0 to 2.5 kHz, 0 to 20 kHz, 0 to 200 Hz, 0 to 24 kHz, 0 to 250 Hz, 0 to 28.8 kHz, 0 to 3 kHz, 0 to 4 kHz, 0 to 400 Hz, 0 to 5 kHz, 0 to 500 Hz, 0 to 6 kHz, 0 to 750 Hz, 0 to 8 kHz
• Minimum operating temperature of -25°C
• Maximum operating temperature of +60°C
• DIN rail mountable
• Screw-type termination for easy use
• Complies with cULus standards for use in hazardous locations
RS PRO
RS PRO is our own brand range and brings you a wide range of high-quality, great value products offering you more choice. Trusted by engineers all over the world, every part of every RS PRO product has been rigorously tested against demanding industry standards
theyre only given the RS PRO Seal of Approval if were confident of their exceptional quality, which means you can be confident too.
Related links
- PR Electronics 5000 Series Signal Conditioner Current Relay Output, 19.2 → 28.8V dc
- RS PRO Signal Conditioner Voltage Input Voltage Output, 16.8 → 30V Supply
- RS PRO Signal Conditioner Current 16.8 → 30V Supply
- RS PRO Signal Conditioner Thermocouple Input Voltage Output, 16.8 → 30V Supply
- PR Electronics 3100 Series Signal Conditioner Voltage Input Voltage Output, 16.8 → 31.2V dc
- Murrelektronik Limited Signal Conditioner Current 10 → 30V dc Supply
- Pepperl + Fuchs S1SD Series Signal Conditioner Voltage Input Voltage Output, 16.8 → 31.2V dc
- WAGO 857 Series Signal Conditioner Current 24V dc Supply