Burkert Solenoid Valve 134438, 2 port , NC, 24 V dc, 1in

  • RS Stock No. 468-043
  • Mfr. Part No. 134438
  • Manufacturer Burkert
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

Two-Way General Purpose Solenoid Valves, Type 5282

The Type 5282 Burkert solenoid valve is specially characterised by its design in which there is fluid separation by the inclusion of a diaphragm seal in the pilot valve. This enables the coil to remain protected from the effects of challenging applications.

Features and Benefits

Less sensitive to dirty fluids and corrosion resistant due to separating diaphragm Suitable for use with neutral gases and liquids
Long-life solenoid system
High reliability
Opening and closing times controlled by integrated restrictor screws
Lockable manual override as standard
NBR seal material
Protection to IP65

Product Application Information

This range of Burkert solenoid valves satisfys the European standards for drinking water.

//media.rs-online.com/t_line/L439060-04.gif

Compact solenoid valves suitable for most gas and fluid handling applications. Where practical, valves are shown with a schematic diagram showing the (circuit) function. The diagram is laid out so that the left-hand side of the diagram describes the valves operation when the coil is energised. When the coil is de-energised, the spring (or servo-assist) return controls the valve and is described on the right-hand side of the diagram. The 3 / 2-way designation indicates a valve with three ports and two modes of operation. It is normal practice to refer to 2 / 2-way valves as two ways. The port designations A, B, P, P1, P2 and R are used on the schematic diagrams and are marked on the valve bodies. Valve bodies are marked for a specific circuit function but can often be used for other functions. Reference to the schematic diagrams and technical specifications indicates the appropriate connections and pressure capabilities when an alternative circuit function is required.

Specifications
Attribute Value
Supply Voltage 24 V dc
Number of Ports 2
Operation Pilot
Connection 1 in G Female
Connection Size 1in
Default Valve Position NC
Suitable Applications Neutral Media
Type 2/2
Orifice Diameter 25mm
Body Material Brass
Maximum Working Pressure 10 bar
Operating Temperature Range 0 → +55 °C
Minimum Operating Temperature 0°C
Maximum Operating Temperature +55°C
Maximum Opening Time 0.8s
Connection Gender Female
Servo Assist Yes
Series 5282
Thread Standard or Connection Type G
Flow Factor Kv 10m³/h
Maximum Closing Time 4s
On back order for despatch 06/08/2020, delivery within 5 working days from despatch date.
Price (ex. GST) Each
$ 704.75
(exc. GST)
$ 810.46
(inc. GST)
units
Per unit
1 +
$704.75
Related Products
Two-way, pilot operated solenoid valves, minimum operating pressure ...
Description:
Two-way, pilot operated solenoid valves, minimum operating pressure required, normally closed with threaded port connection. Brass body. Minimum operating pressure required. Compact & lightweightDIN plug connection Ranging from -20 to +85°CCan be mounted in any position.
Two-way, pilot operated solenoid valves for hot water/steam ...
Description:
Two-way, pilot operated solenoid valves for hot water/steam applications, normally closed with threaded port connection. Brass body. Compact design to minimize heat radiation lossDIN plug connection Ranging from -20 to +184°CCan be mounted in any position.
Parker 2-way solenoid valves are used in a ...
Description:
Parker 2-way solenoid valves are used in a wide variety of applications with or without pressure differential. Ideally suited for air, liquids and gases, these valves are available with a brass or stainless steel body. Compressors. Water dispensing & purification. ...
Isolating diaphragm in FFKM - medium only in ...
Description:
Isolating diaphragm in FFKM - medium only in contact with body and diaphragm. For medical, laboratory and scientific applications - incl. analysis, distribution, dosing, mixing, filling and batching. Miniature design. Low dead volume. Direct acting 2-way normally closed and 3-way ...