Lascar EL-GFX-DTC Temperature Data Logger, USB, 2 Input Channel(s)
- RS Stock No.:
- 775-1073
- Mfr. Part No.:
- EL-GFX-DTC
- Brand:
- Lascar
Subtotal (1 unit)*
$363.00
(exc. GST)
$417.45
(inc. GST)
FREE delivery for orders over $60.00 ex GST
Being discontinued
- Final 10 unit(s), ready to ship from another location
Units | Per unit |
|---|---|
| 1 + | $363.00 |
*price indicative
- RS Stock No.:
- 775-1073
- Mfr. Part No.:
- EL-GFX-DTC
- Brand:
- Lascar
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Lascar | |
| Number of Input Channels | 2 | |
| Model Number | EL-GFX-DTC | |
| Sensor Type | J, K, T, Thermocouple | |
| Measurement Parameters | Temperature | |
| Interface Type | USB | |
| Data Logger Type | Temperature | |
| Maximum Temperature Measurement | +1190 °C, +1350 °C, +2174 °F, +2462 °F, +390 °C, +734 °F | |
| Power Source | Battery | |
| Best Temperature Measurement Accuracy | ±0.5 °C, ±0.9 °F | |
| IP Rating | IP67 | |
| Minimum Operating Temperature | -35°C | |
| Maximum Operating Temperature | +80°C | |
| Display Type | LCD | |
| Temperature Measurement Resolution | 0.1°C | |
| Battery Life | 1 yr | |
| Dimensions | 48.5 x 30.5 x 102mm | |
| Number of Readings Per Channel | 252928 | |
| Model Number p | EL-GFX-DTC | |
| Includes | (2) Batteries, USB Cover, Mounting Clip, (2) TC Probes, Micro USB Cable | |
| Alarm | Yes | |
| Battery Type | 1/2 AA | |
| Select all | ||
|---|---|---|
Brand Lascar | ||
Number of Input Channels 2 | ||
Model Number EL-GFX-DTC | ||
Sensor Type J, K, T, Thermocouple | ||
Measurement Parameters Temperature | ||
Interface Type USB | ||
Data Logger Type Temperature | ||
Maximum Temperature Measurement +1190 °C, +1350 °C, +2174 °F, +2462 °F, +390 °C, +734 °F | ||
Power Source Battery | ||
Best Temperature Measurement Accuracy ±0.5 °C, ±0.9 °F | ||
IP Rating IP67 | ||
Minimum Operating Temperature -35°C | ||
Maximum Operating Temperature +80°C | ||
Display Type LCD | ||
Temperature Measurement Resolution 0.1°C | ||
Battery Life 1 yr | ||
Dimensions 48.5 x 30.5 x 102mm | ||
Number of Readings Per Channel 252928 | ||
Model Number p EL-GFX-DTC | ||
Includes (2) Batteries, USB Cover, Mounting Clip, (2) TC Probes, Micro USB Cable | ||
Alarm Yes | ||
Battery Type 1/2 AA | ||
- COO (Country of Origin):
- CN
Dual-Channel Thermocouple Data Logger
Introducing Lascar's EL-GFX-DTC standalone, USB data logger. This device can record over 250,000 temperature readings from two K, J or T-type thermocouple probes in one or more sessions for up to 4 months.
Your application will determine which probe is the most suitable based on the temperature range, accuracy, form and price needed.
Everything is all in one place with the EasyLog software. Set up your device and in the same place view all your data, graph, print and export recorded data, it's that simple.
The device features a high contrast dot-matrix LCD and three buttons for you to easily navigate through the on-screen menu. The on-screen menu provides you with access to real-time trend analysis, data summaries and the ability to start, stop and restart the data logger without the need to connect the data logger to the host PC. In the device, you can even reset your minimum and maximum readings. This produces an event marker, which can be viewed later in the graphing software and in the data file after download.
Your application will determine which probe is the most suitable based on the temperature range, accuracy, form and price needed.
Everything is all in one place with the EasyLog software. Set up your device and in the same place view all your data, graph, print and export recorded data, it's that simple.
The device features a high contrast dot-matrix LCD and three buttons for you to easily navigate through the on-screen menu. The on-screen menu provides you with access to real-time trend analysis, data summaries and the ability to start, stop and restart the data logger without the need to connect the data logger to the host PC. In the device, you can even reset your minimum and maximum readings. This produces an event marker, which can be viewed later in the graphing software and in the data file after download.
Features and Benefits
Compatible with K, J and T-type thermocouples with miniature thermocouple plug connections
Stores over 250,000 readings
EasyLog software available as a free download
Logging rates between 2 seconds and 1 hour
Supplied with a pair of 1.5m K-type thermocouples with 0 to 200°C (32 to 392°F) measurement range
On-screen graphing, and menu options to start, stop, review and restart the logger in the field
Immediate, delayed, push-button or temperature triggered start mode
Stores over 250,000 readings
EasyLog software available as a free download
Logging rates between 2 seconds and 1 hour
Supplied with a pair of 1.5m K-type thermocouples with 0 to 200°C (32 to 392°F) measurement range
On-screen graphing, and menu options to start, stop, review and restart the logger in the field
Immediate, delayed, push-button or temperature triggered start mode
Applications
Food Temperature Monitoring
Facilities Management
Facilities Management
This item is Lithium cell / battery product (or contains Lithium cells / batteries) which needs to be shipped by sea freight. There will be extension of lead time (around 90 days) for global stock.
Note
The data logger is supplied complete with two lithium metal batteries.
Related links
- Lascar EL-GFX-DTP Temperature Data Logger 2 Input Channel(s)
- Lascar EL-GFX-DTP+ Temperature Data Logger 2 Input Channel(s)
- Lascar EL-GFX-DTP Temperature Data Logger 1 Input Channel(s)
- Lascar EL-GFX-1 Temperature Data Logger 1 Input Channel(s)
- Lascar EL-GFX-TC Temperature Data Logger 1 Input Channel(s)
- Lascar EL-GFX-2+ Temperature & Humidity Data Logger 1 Input Channel(s)
- Lascar EL-GFX-2 Temperature & Humidity Data Logger 1 Input Channel(s)
- Testo 176-T2 Temperature Data Logger 2 Input Channel(s)