Belden, 305 m Cat6 Cat6 Cable, Grey Straight to Unterminated Low Smoke Zero Halogen Sheath, U/UTP

Subtotal (1 reel of 305 metres)*

$1,049.07

(exc. GST)

$1,206.43

(inc. GST)

Add to Basket
Select or type quantity
In Stock
  • 1 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Reel(s)
Per Reel
Per Metre*
1 +$1,049.07$3.44

*price indicative

RS Stock No.:
631-651
Mfr. Part No.:
7965ENH.01305
Brand:
Belden
Find similar products by selecting one or more attributes.
Select all

Brand

Belden

Product Type

Cat6 Cable

Cable Length

305m

LAN Category

Cat6

Shield Type

U/UTP

Connector Type A

Straight

Connector Type B

Unterminated

Jacket Material

Low Smoke Zero Halogen

Jacket Colour

Grey

Standards/Approvals

ISO/IEC 11801-1, IEC 62821, CE, EU

Series

7965ENH

Voltage

72V

COO (Country of Origin):
HU

Belden Power Cable Assembly, 305m Cable Length, Grey Jacket - 7965ENH.01305


This power cable assembly delivers insulated electrical distribution for industrial and commercial installations, providing a shielded Multicore conductor in a low-emission jacket for use where reduced smoke and toxic gas output are required. It is intended for up to 72V systems and deployed in environments that demand compliance with international wiring standards and EU conformity.

Features & Benefits


• U/UTP shielding reduces electromagnetic interference and crosstalk
• Low Smoke Zero Halogen jacket limits harmful emissions in fires
• Rated for 72V systems to support low-voltage power distribution
• CE and EU approved for regulatory acceptance across installations
• Meets ISO/IEC 11801-1 and IEC 62821 standards for structured cabling

**Applications**


• Suitable for factory automation low-voltage power runs
• Ideal for electrical control panel internal wiring
• Used for power distribution in electronic test rigs
• Can be used for mechanical systems requiring reduced-emission cabling

What handling considerations apply for long reels during installation?


Reels of this cable require appropriate cable-pulling techniques and supports to prevent excessive bend radii and tensile stress

secure drum rotation and avoid kinking to maintain conductor integrity.

How does the jacket material influence fire-site conditions?


The low-emission compound produces significantly lower smoke density and reduced corrosive gases compared with conventional PVC, improving visibility and limiting equipment damage during incidents.

What connector preparation is required on-site?


The cable is supplied without terminations, so installers must strip the jacket and prepare individual cores for crimping, soldering or screw termination according to system requirements and safety practices.

Are there screening considerations when routing parallel signal cables?


The unshielded pairs within the screened assembly benefit from the overall U/UTP construction, so maintain separation from high-current conductors and route with the screen earthed at a single point to control noise.

Related links