Alpha Wire Ecogen Ecowire Series Slate 0.52 mm² Hook Up Wire, 20 AWG, 10, 305 m, Modified Polyphenylene Ether, 6714

Bulk discount available

Subtotal (1 reel of 305 metres)*

$741.23

(exc. GST)

$852.41

(inc. GST)

Add to Basket
Select or type quantity
In Stock
  • 4 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Reel(s)
Per Reel
Per Metre*
1 - 24$741.23$2.43
25 - 124$723.05$2.371
125 +$595.07$1.951

*price indicative

RS Stock No.:
741-8102
Mfr. Part No.:
6714 YL001
Brand:
Alpha Wire
Find similar products by selecting one or more attributes.
Select all

Brand

Alpha Wire

Cross Sectional Area

0.52 mm²

Product Type

Hook Up Wire

Jacket Colour

Slate

American Wire Gauge

20AWG

Cable Length

305m

Maximum Operating Temperature

105°C

Conductor Material

Copper

Jacket Material

Modified Polyphenylene Ether

Standards/Approvals

CE, CSA, UL

Minimum Operating Temperature

-40°C

Fire Behaviour

Flame Retardant, Halogen Free, Low Smoke

Series

Ecogen Ecowire

Belden Ecogen Ecowire Series Hook Up Wire, 0.52mm² Cross Sectional Area, Yellow Jacket - 6714 YL001


This hook-up wire is a single-core insulated conductor designed for electrical and control wiring in industrial environments. It combines a copper multi-strand core with a halogen-free thermoplastic jacket to provide reliable connection performance where flame behaviour, low smoke emissions and elevated temperature endurance are required.

Features & Benefits


• Copper conductor with 10 strands for improved flexibility and conductivity
• Cross-sectional area 0.52 mm² for Compact current-carrying capability
• Rated for 600V to support a wide range of control circuits
• Operating range −40°C to 105°C for high-temperature applications
• Modified polyphenylene ether jacket offering chemical and thermal resistance
• Meets IEC 60332-2 flame test and UL VW-1 for flame retardancy

Applications


• Suitable for automation cabinet internal wiring where low smoke is needed
• Ideal for factory machinery control circuits requiring 600V insulation
• Used for wiring in mechanical assemblies with frequent movement
• Can be used for electrical harnesses in environments with temperature variation
• Suitable for industrial installations referencing NFPA 79 safety requirements

What is the conductor construction and how does it affect handling?


The conductor comprises 10 fine copper strands, which enhances flexibility for routing through panels and reduces the risk of breakage during repeated flexing.

Which environmental or regulatory properties are relevant for installation?


Materials comply with RoHS and REACH restrictions and the jacket is halogen-free, reducing hazardous emissions in confined spaces.

How is the product supplied for installation lengths?


It is offered on various spools and reels including continuous lengths of 5,000 ft and shorter put-ups down to 100 ft to suit installation and stocking needs.

What mechanical limits should installers observe during routing?


Maintain a bend radius of 10x cable diameter and avoid exceeding a maximum pull tension of 7.9 lb during installation.

Standards

UL AWM 11028 VW-1, CSA AWM I A/B FT1, RoHS/RoHS2 Compliant, IEC 60332-2 Flame Behavior, REACH Compliant, CE Compliant