Fluke calibration 8808A Bench Digital Multimeter, True RMS, 10A ac Max, 10A dc Max, 750V ac Max
- RS Stock No.:
- 414-193
- Mfr. Part No.:
- Fluke 8808A
- Brand:
- Fluke calibration
Subtotal (1 unit)**
$1,850.20
(exc. GST)
$2,127.73
(inc. GST)
1 In stock for delivery within 1 working day(s)*
* Delivery dates may change based on your chosen quantity and delivery address.
FREE delivery for orders over $80 ex GST
Units | Per unit |
---|---|
1 + | $1,850.20 |
**price indicative
- RS Stock No.:
- 414-193
- Mfr. Part No.:
- Fluke 8808A
- Brand:
- Fluke calibration
Fluke 8808A Multimeter , 5.5 digit
The Fluke 8808A delivers a wide variety of measurement functions, including volts, ohms, and amps, plus frequency - with a basic V dc accuracy of 0.015 %
Six dedicated instrument setup keys to instantly select saved test configurations. Ideal for making routine measurements.
Large and clear Pass and Fail indication based on user defined limits
Extreme ease of use through soft key menu access, ideal for unskilled operators
5.5 digit resolution with 0.015% basic dc V accuracy,
Dual display to measure different signal characteristics such as Volts and Current simultaneously
Dedicated current ranges to measure dc leakage current (i-Leakage mode)
Math Functions: dBm, dB, Min, Max
Patented split terminal jacks for 2x4 Ohms function for precise 4-wire low ohms measurements.
RS-232 Interface
Programming Languages/Modes: Simplified ASCI, Fluke 45
Safety Rating EN61010-1 CAT I 1000 V, CAT II 600 V
Large and clear Pass and Fail indication based on user defined limits
Extreme ease of use through soft key menu access, ideal for unskilled operators
5.5 digit resolution with 0.015% basic dc V accuracy,
Dual display to measure different signal characteristics such as Volts and Current simultaneously
Dedicated current ranges to measure dc leakage current (i-Leakage mode)
Math Functions: dBm, dB, Min, Max
Patented split terminal jacks for 2x4 Ohms function for precise 4-wire low ohms measurements.
RS-232 Interface
Programming Languages/Modes: Simplified ASCI, Fluke 45
Safety Rating EN61010-1 CAT I 1000 V, CAT II 600 V
Note
Accuracy= ± (% of reading+% of range)
Supplied with
Mains lead,TL71 Test Lead Set & users manual on CD-ROM.
Eliminate production mistakes
The Fluke 8808A 5.5 digit multimeter dependably performs the most common measurements required by todays applications. Whether you are performing functional tests or making critical measurements on test points, using the limit compare mode with pass/fail indicators eliminates production mistakes. The 8808A display has built-in enunciators that clearly show the operator whether a test passes or fails. The pass/fail indicators take the guesswork out of testing: the result is either within limits or it is out
Improve quality and efficiency
• Split terminal jacks let you carry out 4-wire measurements using only 2 leads
• Front-panel setup key allows for quick single-key access to saved setups
• Compatible with commonly used power distribution standards, for versatility
• Low-impedance amplifier and current-to-voltage conversion technique, offering accurate low-current leakage detection
• Front-panel setup key allows for quick single-key access to saved setups
• Compatible with commonly used power distribution standards, for versatility
• Low-impedance amplifier and current-to-voltage conversion technique, offering accurate low-current leakage detection
Applications
• Electronics manufacture
• Laboratory-based engineers
• Factories and workshops
• Laboratory-based engineers
• Factories and workshops
Manufacturing test, R&D, development and service applications demand performance and flexibility from a bench meter. This Fluke 8808A makes measurements that stand up to any scrutiny. It delivers a wide variety of measurement functions, including volts, ohms, and amps, plus frequency—all at superior accuracy and resolution.
Measure two parameters at once
The 8808A features a unique dual display that allows you to measure two different parameters of the same signal from one test connection. Looking at dual interrelated parameters like voltage and current simultaneously can reveal conditions that might go unnoticed otherwise, greatly simplifying test and troubleshooting.
Yes, this multimeter comes with a handle. If you're looking for a smaller hand-held unit, explore FLUKE's range of rugged industrial field devices (such as 606-3041).
Measure sensitive leakage current
Typical multimeters use a shunt method to measure current, creating a measurement burden voltage that increases the error in low current measurements. This makes it difficult, if not impossible, to perform tasks such as determining the true leakage current on a battery-powered device while it is powered down, or measuring small currents in sensitive circuits. The Fluke 8808A is the only multimeter in its class to use a low-impedance operational amplifier and current-to-voltage conversion technique to eliminate the burden voltage and measure sensitive low currents. In this special mode, the 8808A can accurately measure small currents with a resolution of up to 100 nA.
Perform 4-wire measurements with only two leads
Patented split terminal jacks for the 2x4-wire ohms function allow you to perform 4-wire measurements using only two leads instead of four. Todays surface mount components make it difficult to make connections. The task becomes even more difficult when you need to use a 4-wire technique for accurate low ohms measurements. The Fluke test lead accessory combines the four wires into two test lead pairs, making it easy for you to establish connections. You get excellent resolution and accuracy, plus the convenience and ease of using a single pair of leads.
Attribute | Value |
---|---|
Multimeter Type | Bench |
Display Type | Digital |
Model Number p | 8808A |
Functions Measured | AC Current, AC Voltage, Continuity, DC Current, DC Voltage, Diode, Frequency, Resistance |
Absolute Maximum DC Voltage Measurement | 1000V dc |
Absolute Maximum DC Current Measurement | 10A dc |
Absolute Maximum Resistance Measurement | 100MΩ |
Absolute Maximum AC Voltage Measurement | 750V ac |
Absolute Maximum AC Current Measurement | 10A ac |
Maximum Frequency | 100kHz |
DC Current Measurement Resolution | 0.001µA dc |
AC Current Measurement Resolution | 0.1µA ac |
Resistance Measurement Resolution | 1mΩ |
AC Voltage Measurement Resolution | 1µV ac |
DC Voltage Measurement Resolution | 1µV dc |
Best AC Voltage Accuracy | ±0.9% + 0.05 Digits |
Minimum Operating Temperature | 0°C |
Height | 88mm |
Best AC Current Accuracy | ±0.5% + 0.12 |
Maximum Operating Temperature | +50°C |
Dimensions | 297 x 217 x 88mm |
Best DC Voltage Accuracy | ±0.015% + 0.003 |
Width | 217mm |
Best Resistance Measurement Accuracy | ±1.75% + 0.004 |
Length | 297mm |
Best DC Current Accuracy | ±0.2% + 0.01 |
Weight | 2.1kg |
RoHS Status: Exempt
- COO (Country of Origin):
- CN